13
(2)  Press the 2   marks on the frame cover and disengage 
the stationary tabs from the frame. (Fig. 3-32)
Fig. 3-32
(3)  Remove the rear panel.
NOTE
Tubing can be extended in 5 directions as shown in Fig. 3-33. 
Select the direction you need providing the shortest run to the 
outside unit.
Fig. 3-33
●  When left tubing is to be done, switch the drain hose and 
drain cap. (For details, refer to “Switching drain hose and 
drain cap”.)
3-12. Make a Hole
(1)  Place the rear panel from the indoor unit on the wall at the 
location selected. Make sure the panel is horizontal, using 
a carpenter’s level or tape measure to measure down from 
the ceiling. Wait until after cutting the hole before attaching 
the rear panel to the wall.
(2)  Determine which side of the unit you should make the hole 
for tubing and wiring. (Fig. 3-34) 
70 mm
Fig. 3-34
NOTE
In the case of left-rear tubing, use the measurement points from 
the edge of the rear panel for precise placement of the hose 
outlet. (Fig. 3-34)
(3)  Before making the hole, check carefully that no studs or 
pipes are directly run behind the spot to be cut.
CAUTION
Also avoid areas where electrical wiring or conduits are 
located.
The above precautions are also applicable if tubing goes 
through the wall in any other location.
(4)  Using a sabre saw, key hole saw or hole-cutting drill 
attachment, cut a hole in the wall. (Fig. 3-35)
Fig. 3-35
NOTE
Hole should be made at a slight downward slant to the outdoor 
side.
Table 3-2
Hole Dia. (mm)
S-22MK1E5 / S-28MK1E5 / S-36MK1E5
65
(5)  Measure the thickness of the wall from the inside edge to 
the outside edge and cut PVC pipe at a slight angle 6 mm 
shorter than the thickness of the wall. (Fig. 3-36)
Fig. 3-36
(6)  Place the plastic cover over the end of the pipe (for indoor 
side only) and insert the pipe in the wall. (Fig. 3-37)
Fig. 3-37
Rear panel
 marks
Left 
tubing
Left-rear 
tubing
Downward tubing
Right tubing
Right-rear 
tubing
(recommended)
Indoor
side
Outdoor
side
PVC pipe (Locally purchased)
Cut at slight angle
INSIDE
Plastic cover
(Locally purchased)
Wall
PVC pipe
Slight
angle
OUTSIDE
PanaIndoor-337012Eng.indb13PanaIndoor-337012Eng.indb13 2012/03/2116:20:462012/03/2116:20:46