How to connect wiring to the terminal
Q
For stranded wiring
(1) Cut the wire end with cutting pliers,
then strip the insulation to expose
the stranded wiring about 10 mm and
tightly twist the wire ends. (Fig. 4-7)
(2) Using a Phillips head screwdriver,
remove the terminal screw(s) on the
terminal plate.
(3) Using a ring connector fastener or
pliers, securely clamp each stripped
wire end with a ring pressure
terminal.
(4) Place the ring pressure terminal,
and replace and tighten the removed
terminal screw using a screwdriver.
(Fig. 4-8)
Q Examples of shield wires
(1) Remove cable coat not to scratch braided shield. (Fig. 4-9)
(2) Unbraid the braided shield carefully and twist the unbraided
shield wires tightly together. Insulate the shield wires by
covering them with an insulation tube or wrapping insulation
tape around them. (Fig. 4-10)
(3) Remove coat of signal wire. (Fig. 4-11)
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2). (Fig. 4-12)
Fig.4-8
Stranded wire
Screw
Special
washer
Strip 10 mm
Ring
pressure
terminal
Wire
Wire
Ring pressure
terminal
Terminal plate
Screw and
Special washer
Ring
pressure
terminal
Fig.4-7
Insulation tape Shield mesh
Fig.4-9
Fig.4-10
Fig.4-12
Insulation tape Shield mesh
8 mm
Fig.4-11