EasyManua.ls Logo

Panasonic S-36PN1E5

Panasonic S-36PN1E5
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
ENGLISH

E PORTUGUÊS


O Check Before Requiring Services
Symptom Cause Remedy
Air conditioner does not
run at all although power
is turned on.
Power failure or after power failure Press ON/OFF operation button on remote control unit again.
Operation button is turned off.
O Switch on power if breaker is turned off.
O If breaker has been tripped, consult your dealer without
turning it on.
Fuse blow out. If blown out, consult your dealer.
Poor cooling or heating
performance.
Air intake or air discharge port of indoor
and outdoor units is clogged with dust or
obstacles.
Remove dust or obstruction.
Wind speed switch is set to “Low”. Change to “High” or “Strong”.
Improper temperature settings Refer to Q Tips for Energy Saving”.
Room is exposed to direct sunlight in
cooling mode.
Doors and /or windows are open.
Air filter is clogged. Refer to QCare and Cleaning”.
Too much heat sources in room in cooling
mode.
Use minimum heat sources and in a short time.
Too many people in room in cooling mode. Reduce temperature settings or change to “High” or “Strong”.
If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and turn off
the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by yourself since it
is very dangerous for you to do so.
Q Tips for Energy Saving
Avoid
O Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
O Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it
will take longer to cool the room.
Do
O Always try to keep the air fi lter clean. (Refer to “Care and Cleaning”.) A clogged fi lter will impair the performance of the unit.
O To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
NOTE
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same
settings before the power was interrupted.
P07-T11630.indb 25 2/27/2012 9:21:21 AM

Other manuals for Panasonic S-36PN1E5

Related product manuals