100
200
300
400
500
600
700
800
-30 -20 -10 0 10
Evaporating Temperature (°F)
Capacity (BTU/H)
110°F 120°F 130°F
55
75
95
115
135
-30 -20 -10 0 10
Input Power (W)
Rated Performance Data
Capacity . . . . . . . . . . . . . . 420 Btu/h ±7% *
E.E.R. . . . . . . . . . . . . . . . . . 4.56 Btu/Wh ±10% *
Current . . . . . . . . . . . . . . . 0.82 Amps *
Nominal Motor Data Motor Input . . . . . 92 Watts*
Rated Current . . . 0.84 Amps
Type . . . . . . . . . . RSCR, PTC relay
Locked Rotor . . . . . . . . . . 6.62 Amps
Start Current . . . . . . . . . . 13.85 Amps
Coil Resistances Run . . . . 5.34 Ohms
@ 68°F (20°C) Start . . . 6.57 Ohms
*Test Conditions for Performance Specifications
Test Oil . . . . . . . . . . . . . . . . Freol α 10
Shell Temp . . . . . . . . . . . . . . 150.0°F / 65.0°C
Condensing Temp . . . . . . . . . 130.0°F / 54.4°C
Evaporating Temp . . . . . . . . .-10.0°F / -23.3°C
Ambient Temp . . . . . . . . . . . . 90.0°F / 32.2°C
Gas Superheat . . . . . . . . . . . 90.0°F / 32.2°C
Liquid Sub-Cooling . . . . . . . . 90.0°F / 32.2°C
Electrical Accessories
Overload Protector
Nominal Operating Characteristics
Model Name T135AH3
.
1
Manufacturer Matsushita
Temperature To . . . . . . . . . . . Open: 275°F ± 9°F / 135°C ± 5°C
Close: 176°F ± 27°F / 80°C ± 15°C
Trip Current . . . . . . . . . . . . . . @212°F (100°C) 3.5 to 4.5 Amps
@77°F (25°C) 11.7 Amps @ 13 sec. max.
P.T.C. Starting Device
Nominal Operating Characteristics
Model Name MM8-5DCP4M7 PTH7M4R7MD2
Manufacturer Matsushita Murata Mfg.
Base resistance
@ 77°F(25°C) ±20% 4.7 4.7 Ohms
Power Consumption (max) 3.3 3.0 Watts
Operation time 1.3 to 3.0 0.7 to 2.2 seconds
Recovery time (max) 65 70 seconds
Run Capacitor 12 µF 180 V (min.)
†Although these accessories are listed by UL/CSA for use with this compressor,
Matsushita assumes no responsibility whatsoever for these or any other components
sourced by the refrigeration system manufacturer from third parties.
Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9
Evaporating Temp.
Condensing Temp. Rating -30°F -10°F +10°F
130°F Btu/h 164 420 758
Watts 59 92 126
Amps 0.53 0.82 1.12
E.E.R. 2.78 4.57 6.02
120°F Btu/h 195 437 768
Watts 63 89 120
Amps 0.56 0.79 1.08
E.E.R. 3.10 4.91 6.40
110°F Btu/h 222 451 778
Watts 65 86 115
Amps 0.57 0.76 1.03
E.E.R. 3.42 5.24 6.77
MATSUSHITA Compressor Single Phase 115V
MODEL# SD39C66JBU6 (12µF Run Cap. - VG10) R-134a 60
Hz
Performance Curves
Voltage Range . . . . . . . . . 103 Volts to 127 Volts @ 60 Hz
Application . . . . . . . . . . . . Low Back Pressure
Compressor Cooling . . . . Static Cooling
Refrigerant Control . . Capillary Tube
Evaporator
Temp. Range . . . . . . . -31°F to 23°F / -35°C to -5°C
9 – Point Data
P
a
na
s
o
n
ic
®
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
-30 -20 -10 0 10
Current (A)
Question and Answer IconNeed help?

Do you have a question about the Panasonic SD39C66JBU6 and is the answer not in the manual?

Panasonic SD39C66JBU6 Specifications

General IconGeneral
BrandPanasonic
ModelSD39C66JBU6
CategoryAir Compressor
LanguageEnglish

Summary

Rated Performance Data

Capacity, E.E.R., and Current

Key performance metrics including cooling capacity, energy efficiency, and current draw.

Nominal Motor Data

Details on motor input power, rated current, and type (RSCR, PTC relay).

Locked Rotor and Coil Resistance

Specifications for locked rotor current and coil resistance at operating temperature.

Test Conditions for Performance

Performance Specification Conditions

Specifies test oil, shell, condensing, evaporating, and ambient temperatures for performance evaluation.

Electrical Accessories

Overload Protector Details

Information on the overload protector's model, manufacturer, and operating characteristics.

PTC Starting Device Specs

Details on the PTC starting device, including model, manufacturer, base resistance, and operation timing.

Performance Curves Overview

Input Power vs. Evaporating Temperature

Graph showing compressor input power variation with evaporating temperature.

Current vs. Evaporating Temperature

Graph illustrating compressor current draw based on evaporating temperature.

Capacity vs. Evaporating Temperature

Graph depicting compressor capacity output relative to evaporating temperature.

9-Point Performance Data

Data Table by Temperature

Tabulated performance data (Btu/h, Watts, Amps, E.E.R.) across various condensing and evaporating temperatures.

Dimensions

Overall Compressor Dimensions

Detailed measurements (A-E) of the compressor unit in millimeters and inches.

Tube Specifications

Outer diameter, wall thickness, and material for suction, process, and discharge tubes.

General Data

Oil Charge and Net Weight

Information on the recommended oil charge quantity and the compressor's net weight.

Approved Oils

List of approved refrigerant oil types for use with the compressor.

Contamination Limits

Specifications for maximum residual moisture and impurities allowed in the system.

Compressor Displacement

The swept volume or displacement of the compressor in cubic centimeters and cubic inches.

Related product manuals