EasyManua.ls Logo

Panasonic SD51C10JAU6

Panasonic SD51C10JAU6
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
-30 -20 -10 0 10
Current (A)
80
100
120
140
160
180
-30 -20 -10 0 10
Input Power (W)
200
300
400
500
600
700
800
900
1,000
-30 -20 -10 0 10
Evaporating Temperature (°F)
Capacity (BTU/H)
110°F 120°F 130°F
Rated Performance Data
Capacity . . . . . . . . . . . . . . 567 Btu/h ±10% *
E.E.R. . . . . . . . . . . . . . . . . . 4.46 Btu/Wh ±10% *
Current . . . . . . . . . . . . . . . 1.27 Amps *
Nominal Motor Data Motor Input . . . . . 127 Watts*
Rated Current . . . 1.28 Amps
Type . . . . . . . . . . RSCR, PTC relay
Locked Rotor . . . . . . . . . . 10.30 Amps
Start Current . . . . . . . . . . 18.29 Amps
Coil Resistances Run . . . . 3.45 Ohms
@ 68°F (20°C) Start . . . 5.36 Ohms
*Test Conditions for Performance Specifications
Test Oil . . . . . . . . . . . . . . . . Freol α 22
Shell Temp . . . . . . . . . . . . . . 170.0°F / 76.0°C
Condensing Temp . . . . . . . . . 130.0°F / 54.4°C
Evaporating Temp . . . . . . . . .-10.0°F / -23.3°C
Ambient Temp . . . . . . . . . . . . 90.0°F / 32.2°C
Gas Superheat . . . . . . . . . . . 90.0°F / 32.2°C
Liquid Sub-Cooling . . . . . . . . 90.0°F / 32.2°C
Electrical Accessories
Overload Protector
Nominal Operating Characteristics
Model Name T130AH6
.
1
Manufacturer Matsushita
Temperature To . . . . . . . . . . . Open: 266°F ± 9°F / 130°C ± 5°C
Close: 176°F ± 27°F / 80°C ± 15°C
Trip Current . . . . . . . . . . . . . . @212°F (100°C) 3.8 to 4.8 Amps
@77°F (25°C) 16.5 Amps @ 13 sec. max.
P.T.C. Starting Device
Nominal Operating Characteristics
Model Name PTH490D-AS4R7 PTH7M4R7MD2
Manufacturer Murata Mfg. Murata Mfg.
Base resistance
@ 77°F(25°C) ±20% 4.7 4.7 Ohms
Power Consumption (max) 3.3 3.0 Watts
Operation time 1.3 to 3.0 0.7 to 2.2 seconds
Recovery time (max) 65 70 seconds
Run Capacitor 12 µF 180 V (min.)
†Although these accessories are listed by UL/CSA for use with this compressor,
Matsushita assumes no responsibility whatsoever for these or any other components
sourced by the refrigeration system manufacturer from third parties.
Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9
Evaporating Temp.
Condensing Temp. Rating -30°F -10°F +10°F
130°F Btu/h 270 567 994
Watts 88 127 170
Amps 0.95 1.27 1.62
E.E.R. 3.07 4.46 5.85
120°F Btu/h 297 587 1,004
Watts 90 124 162
Amps 0.96 1.24 1.54
E.E.R. 3.30 4.73 6.20
110°F Btu/h 318 597 1,011
Watts 90 120 155
Amps 0.96 1.20 1.48
E.E.R. 3.53 4.98 6.52
MATSUSHITA Compressor Single Phase 115 V
MODEL# SD51C10JAU6 R-134a 60
Hz
Performance Curves
Voltage Range . . . . . . . . . 103 Volts to 127 Volts @ 60 Hz
Application . . . . . . . . . . . . Low Back Pressure
Compressor Cooling . . . . Static Cooling
Refrigerant Control . . Capillary Tube
Evaporator
Temp. Range . . . . . . . -31°F to 23°F / -35°C to -5°C
9 – Point Data
P
a
na
s
o
n
ic
®
Question and Answer IconNeed help?

Do you have a question about the Panasonic SD51C10JAU6 and is the answer not in the manual?

Panasonic SD51C10JAU6 Specifications

General IconGeneral
BrandPanasonic
ModelSD51C10JAU6
CategoryAir Compressor
LanguageEnglish

Summary

Rated Performance Data

Compressor Capacity

Rated cooling capacity of the compressor, measured in Btu/h with a tolerance.

Energy Efficiency Ratio (E.E.R.)

Measures compressor efficiency in Btu per Watt-hour, indicating energy performance.

Compressor Current Draw

The electrical current the compressor draws during operation, measured in Amps.

Nominal Motor Data

Motor Input Power

The electrical power consumed by the compressor motor, measured in Watts.

Rated Motor Current

The expected electrical current the motor will draw under rated conditions, in Amps.

Motor Type and Resistance

Specifies motor type (RSCR, PTC relay) and winding resistances (start/run) in Ohms.

Test Conditions for Performance

Test Parameters Overview

Specifies test oil type and critical temperature parameters for compressor testing.

Gas Superheat and Liquid Sub-Cooling

Defines superheat and sub-cooling conditions for performance evaluation.

Electrical Accessories

Overload Protector Specifications

Details the overload protector's model, manufacturer, and trip points.

PTC Starting Device Details

Information on the PTC starting device, including model, manufacturer, and operational timings.

Run Capacitor Requirement

Specifies the minimum capacitance and voltage rating for the run capacitor.

Performance Curves

Input Power vs. Evaporating Temperature

Graphical representation of compressor input power (W) across various evaporating temperatures (°F).

Current vs. Evaporating Temperature

Graph showing compressor current draw (A) as a function of evaporating temperature (°F).

Capacity vs. Evaporating Temperature

Illustrates compressor cooling capacity (BTU/H) plotted against different evaporating temperatures (°F).

9 - Point Data

Performance Data at Various Temperatures

Detailed performance metrics (Btu/h, Watts, Amps, E.E.R.) at specific condensing and evaporating temperatures.

Compressor Dimensions and Mounting

Dimensional Drawings

Provides detailed measurements and diagrams for compressor mounting and connections.

Tube Specifications

Details the outer diameter, wall thickness, and material for suction, process, and discharge tubes.

Electrical Connections and Components

R.S.C.R. Motor Wiring Diagram

Schematic showing the R.S.C.R. motor, internal protector, PTC relay, and running capacitor connections.

Certifications and General Data

UL and CSA File Information

Lists the UL and CSA file numbers for product certification and compliance.

General Operating Data

Includes oil charge, net weight, approved oils, residual moisture, impurities, and displacement.