5
SR-TEJ10, SR-TEJ18
Condition Troubleshooting Remedy
● Earlier cutoff
● Poor boiling-up
Too hard
Too soft
Cored rice
Insufficient boiling
Is the pan bottom properly
contacted with the cast heater?
(Check with the bubbling test.)
● Replace the inner pan or the
cast heater.
Does the center thermostat
operate properiy? (Check with
the operation test.)
● Replace Center thermostat.
Is the rice boiling control lever
properly adjusted?
● Adjust control lever.
Is the cast heater conductive?
● Replace the cast heater.
Improper operation
●
Rice is excessive or insufficient.
●
Water is excessive or insufficient.
● The switch is turned off once
during boiling.
● Immediately after the switch is
turned off, open the cap.
●
Rice has not been scooped and
mixed well.
● Explain the proper operation.
● Excessive burning (More
than light brown)
Does the center thermostat
operate properly?
(Check with the evaporation test.)
● Replace the center thermostat.
Is the rice boiling control lever
properly adjusted?
● Adjust the control lever.
Improper
● Rice is not washed sufficiently.
(Bran remains still.)
● The pan bottom is conditioned
to generate burning easily.
● Germ rice or wheat-mixed rice
is boiled.
● Mixed rice boiled.
●
The voltage is lower than specified.
● Water is excessive.
● Explain the proper operation.
YES
NO
YES
NO
YES
NO
YES
NO
NO
YES
NO
YES
NO
YES