14
7.2. Disassembly Procedure for the Unit
7.2.1. Remove the Pedestal stand
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
2. Remove the screws (×4 ).
3. Slide the Pedestal stand to the downside and remove the
Pedestal stand.
7.2.2. Remove the AC cord clamper B
1. Remove the screws (×2 ) and remove the AC cord
clamper B.
7.2.3. Remove the Rear cover
1. Remove the screws (×24 , ×6 , ×2 ).
2. Remove the M8 caps (×4 ).
3. Remove the Rear cover.
7.2.4. Remove the Key button
1. Remove the screws (×2 ).
2. Remove the Key button.
7.2.5. Remove the PSS-Board
Caution:
To remove P.C.B. wait 1 minute after power was off for
discharge from electrolysis capacitors.
1. Disconnect the connectors (P2 and P35).
2. Disconnect the bridge connector (A6-P6).
3. Disconnect the flexible cables (SS52 and SS55).
4. Remove the screws (×5 , ×1 , ×1 ) and remove
the PSS-Board.