Reset and Self-check Procedure
57
How to access the self-check
screen to reset the unit.
Select a television channel, and while
pressing the [VOLUME ( - )] button on
the main unit, press the [OK] button on
the remote control for more than 3
seconds.
How to Exit the self-check
screen
Disconnect the AC cord from the wall
outlet.
All parameters of the unit are now set
to factory default.
Self-check Screen
CHASSIS: GP9D and GPH9D
All models
TH-42PD60U Driver Setup Adjustment
Adjustment
Voltage
58
Driver Setup Table
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu: Vivid
Picture: +30
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. The Confirmation of Vscn voltage should be performed
after the confirmation of Vad adjustment.
When Vad=-90V, Voltage of Vscn is 30V ±3V.
Panel Label
Initialization Pulse Adjust
1. Input the White signal to plasma video
input.
2. Set the picture controls as follows.
Picture menu : Vivid
Picture : +25
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T2)
and adjust VR6602 for 195+10ˤ Sec.
Test point Volume Level
T2 TPSC1 (SC) VR6602 (SC 170 ± 10ˤ Sec