Loading...
LED blinks 2 times (TH-50PX60U\600U, TH-58PX60U\600U, TH-65PX600U)
<Trouble Mode and Defective Board>
Trouble Mode
15V down SOS
Defective Board (Possibility)
P, D, PA, SC, SS Board (P > PA, D, SC, SS)
<How to find the defective boards>
Turn the unit on.
Is there 15V output
at CN P25 pin 1 or 2 before
Shutdown ?
D Board
SC Board
D Board
Yes
No
No
P Board
PA Board
Power SW OFF.
Disconnect CN P25. Check
pin 1 or 2 of the socket for a
Short to GND?
No
Yes
No
Yes
Turn the unit on.
Does the power LED
blink 2 times?
With the power SW OFF, disconnect
CN SC23, SC20, and SC2. To isolate
the SC board.
With the power SW OFF, disconnect CN P12, SS11, and SS43
(*1). to isolate the SS board. Remove the jumper at CN SS34
and install it across pin 8 and 10 of connector P12.
SS Board
No
Turn the unit on.
Does the power LED
blink 2 times?
Yes
With the power SW OFF, disconnect
CN P5. To isolate the PA board
board.
Turn the unit on.
Does the power
LED blink 2 times? The
power LED may blink 12
times.
Warning: Disconnect AC Power prior to
making any disconnection or
connection.
(*1) = The reference number of the sustain data
connector is different in some of the models:
TH-50PX60U = SS43
TH-50PX600U = SS43
TH-58PX60U = SS44
TH-58PX600U = SS44
TH-65PX600U = SS44
9
LED blinks 3 times
<Trouble Mode and Defective Board>
Trouble Mode
3.3V down SOS
Defective Board
D Board
<How to find the defective boards>
In this case, the defective board is D board only.
Warning: Disconnect AC Power prior to
making any disconnection or
connection.
10

Table of Contents

Other manuals for Panasonic TH-37PX60U

Related product manuals