EasyManua.ls Logo

Panasonic TH-42LRG20E - Setting Inspection

Panasonic TH-42LRG20E
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting Inspection
Voltage Confirmation
* Connect AC 230V to P1 connector in down-right corner of P-PCB
** Connect DC 3.3V to TV_SUB_ON P2 connector – pin 9 (TP809).
*** Connect DC 3.3V to TV_MAIN_ON P2 connector – pin 10 (TP808).
A board
Description Test point Voltage
SUB1.8V TP5601 1.76V – 1.87V
SUB1.2V TP5600 1.18V – 1.29V
SUB3.3V TP5602 3.19V – 3.39V
SUB5V TP5200 4.9V – 5.1V
SUB9V TP5220 8.82V – 9.27V
STB5V TP5400 4.9V – 5.1V
P board
Description Test point Voltage
* ** ***
24V_INV TP807 < 1V 24V ± 1V 24V ± 1V
17V TP806 < 1V 16,5V ± 1,5V 16,5V ± 1,5V
12V TP805 < 0.5V 12V ± 1V 12V ± 1V
STB_5V8/TUNER5V8 TP803 5.7V ± 0.3V 5,7V ± 0,3V 5,7V ± 0,3V
400V TP800 n/a < 340V 395 ± 20V
11