EN36
Before Replacing the Cartridge (continued)
Even if U25 or U26 is not displayed, replace the cartridge when:
The water has an unpleasant odor or taste (this means that the cartridge’s ability to fi lter out these
impurities has deteriorated).
The period of time (about 1 year) that serves as a general guideline for when to replace the
cartridge has passed.
Period of time serving as a general guideline for when to replace the cartridge (for
a year using 30 liters per day)
(Replacement cartridge: Model number TK-AS45C1-EX) (P. EN49)
Replacement guideline Substances removed by cartridge
About 1 year
Free residual chlorine, turbidity, total trihalomethane, chloroform,
bromodichloromethane, dibromochloromethane, bromoform,
tetrachloroethylene, trichloroethylene, 1,1,1-trichloroethane, CAT,
2-MIB (mold smell), soluble lead
Diff erences in usage period by water quality
Inside the cartridge is a hollow fi ber membrane fi lter for removing microscopic dirt. The cartridge’s life
will be shortened when the Alkaline Ionizer is used with a quality of water containing many clogging
substances.
Hollow fi ber membrane
surface (new fi lter)
Clogged hollow fi ber
membrane surface
Clogging
guideline
Volume of
water purifi ed
Total volume of
run-through water
(1) Water containing
many clogging
substances
(2) Water with
standard quality
Note
The volume of water coming out of the Alkaline Ionizer may be reduced when:
The water temperature is low (because the water does not run through the cartridge so easily).
The Alkaline Ionizer is used in areas where the water pressure is low (under 70 kPa).
The pressure of the tap water has dropped because of the demand for tap water in the area concerned.
Immediately after a period when the water supply was shut off such as during plumbing work.