EN41
When necessary
English
Rated voltage, frequency, input current 220-240 V ~ , 50 Hz, 0.65 A
Rated power consumption Approx. 130 W (approx. 1 W during standby)
Main unit
Dimensions
Approx. 180(W) × 115(D) × 328(H) mm
(Depth including LCD display: 123 mm)
Weight Approx. 3.8 kg (approx. 4.3 kg when full of water)
Temperature of water used by Alkaline Ionizer
Under 35 °C (under 80 °C for bypass selector)
Pressure of water used by Alkaline Ionizer (dynamic pressure)
70 kPa to 350 kPa
Usable water service pressure (static pressure)
70 kPa to 750 kPa
Electrolysis
Electrolysis method Continuous electrolysis
Output water volume
(fl ow of water produced)
Alkaline water : 1.5 L/min. [at 100 kPa water pressure] (“Standard” mode)
Weak acidic water : 1.3 L/min. [at 100 kPa water pressure]
Electrolysis capability selection
Alkaline: 4 levels; weak acidic: 2 levels
Continuous operation
capability
Approx. 10 minutes at room temperature (Note 1)
Electrolyzer life
Approx. 850 hours cumulative
(ion water production time, cleaning time only)
Electrolytic cleaning Auto cleaning method
Purifi ed water output volume 1.6 L/min. [at 100 kPa water pressure]
Filtration fl ow volume 1.6 L/min. [at 100 kPa water pressure] (Note 2)
Cartridge Installed In the unit TK-AS700C-EX
Purifi cation capacity
Free residual chlorine 6 000 L
(Note 2,3)
Turbidity 6 000 L
(Note 2,4)
Chloroform 6 000 L
(Note 2,5)
Total trihalomethane 6 000 L
(Note 2,5)
Bromodichloromethane 6 000 L
(Note 2,5)
Dibromochloromethane 6 000 L
(Note 2,5)
Bromoform 6 000 L
(Note 2,5)
Tetrachloroethylene 6 000 L
(Note 2,5)
Trichloroethylene 6 000 L
(Note 2,5)
CAT (pesticide) 6 000 L
(Note 2,3)
2-MIB (mold smell) 6 000 L
(Note 2,3)
Soluble lead 6 000 L
(Note 2,3)
1,2-DCE 6 000 L
(Note 2,5)
Benzene 6 000 L
(Note 2,5)
Geosmin (mold smell) 6 000 L
(Note 2,3)
Phenols 6 000 L
(Note 2,3)
Carbon tetrachloride 6 000 L
(Note 2,6)
Removable substances
Iron (particulate form) Can be removed
(Note 7)
Aluminium (neutral) Can be removed
(Note 7)
Guide for time to replace cartridge Approx. 1 year
(Note 8)
Filter material
Non-woven fabric, ceramic, activated carbon, hollow fi ber membrane
Components which cannot be fi ltered out
Iron dissolved in water, heavy metals (silver, copper, etc.), salt (seawater)
Length of power cord Approx. 3 m
Power protection device Current fuse: 2.5 A
* All fi gures given are for a water temperature of 20 °C. * This product cannot convert hard water into soft water.
*
The total volume of water coming out of the main spout, drain hose is given as the run through water volume and daily volume of water used.
* Activated carbon uses powdered activated carbon and granular activated carbon.
(Note1) This period may be shorter depending on the water quality and usage environment.
(Note2)
The amount of water that can be used with Alkaline 1 to 3 in Standard Milder mode is equivalent to about 94 % of the fi ltration fl ow volume
(water purifying capacity)
.
(Note3) This value is for a removal rate of 80 % based on JIS S 3201 tests.
(Note4) This value is for a fi ltration fl ow volume of 50 % based on JIS S 3201 tests.
(Note5) This value is for a removal rate of 80 % based on JIS S 3201 Annex A tests.
(Note6) This value is for a removal rate of 80 % based on specifi cation standard tests (JWPAS B standards) stipulated by the Japan
Water Purifi er Association (JWPA).
(Note7) This substance is for a removal rate of 80 % based on specifi cation standard tests (JWPAS B standards) stipulated by the Japan
Water Purifi er Association (JWPA). Note that it is not stipulated as part of purifi cation capacity.
(Note8)
This period applies when 15 liters of water are used a day. If 30 liters are used a day, the cartridge usage limit will be approximately one-half.
The period may also be signifi cantly less depending on the amount of water used and on its quality and pressure.
Specifi cations
TK-AS700_En.indb 41TK-AS700_En.indb 41 2022/04/14 18:18:092022/04/14 18:18:09