19.2.4. WH-SDC14C6E5 WH-UD14CE5-A
19.2.5. WH-SDC16C6E5 WH-UD16CE5-A
19.3. Cooling Capacity Table
LWC303540455055
Tamb HC IP HC IP HC IP HC IP HC IP HC IP
-15 9.90 3.91 9.50 4.05 9.00 4.19 8.60 4.33 7.90 4.45 7.30 4.56
-7 11.10 3.73 10.70 4.08 10.20 4.43 9.80 4.78 9.10 4.76 8.50 4.74
2 12.90 3.51 12.40 3.73 11.90 3.95 11.40 4.17 10.40 4.29 9.50 4.40
7 14.00 2.60 14.00 3.11 14.00 3.63 14.00 4.14 13.60 4.61 13.30 5.08
25 14.00 1.75 14.00 2.10 14.00 2.45 14.00 2.80 14.00 3.05 14.00 3.44
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
LWC303540455055
Tamb HC IP HC IP HC IP HC IP HC IP HC IP
-15 10.60 4.13 10.30 4.42 10.00 4.71 9.70 5.00 8.80 4.98 7.90 4.95
-7 11.90 4.07 11.40 4.47 10.80 4.87 10.30 5.26 9.60 5.13 9.00 4.99
2 13.50 3.78 13.00 4.00 12.40 4.22 11.90 4.44 10.80 4.50 9.80 4.55
7 16.00 3.25 16.00 3.78 16.00 4.31 16.00 4.84 15.20 5.15 14.50 5.45
25 16.00 2.35 16.00 2.73 16.00 3.11 16.00 3.49 16.00 3.71 15.90 3.93
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
MODELS SDC07 SDC09 SDC12 SDC14 SDC16
LWC77777
Tamb TC IP TC IP TC IP TC IP TC IP
16 5.09 0.88 5.93 1.07 9.35 1.91 10.16 2.05 10.57 2.15
25 6.58 1.75 7.79 2.25 9.17 2.30 10.06 2.68 10.52 2.86
35 6.13 2.33 7.01 2.92 9.84 3.48 11.45 4.37 12.23 4.79
43 5.14 2.69 6.20 3.28 7.60 3.95 9.06 5.02 10.09 5.47
TC: Cooling Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)