PROBLEM POSSIBLE CAUSE SOLUTION
Front panel displays
- “E0”, “E1”. “E2”,
“E3”,
“E4”, “E5”, “E6”.
Error codes
Try to restore the controls with a
"Reset". (Disconnect from the mains for
5 minutes)
If the problem persists, call Technical
Service.
Front panel displays
- “E7”.
Indicates the door switch failure
Check that the door closes properly
and that the sensor is not dirty or
obstructed.
The alarm sounds
and the display is
flashing
Has the door been open for more than 60
seconds?
If this is the case, close the door.
If not, the temperature has risen or has
fallen below the temperature established.
This may have been due to:
The door is opened very often.
The ventilation opening is obstructed or
contains too much dust.
A long power cut.
Many of bottles have just been added to
the unit.
Do not open the door more than
necessary.
Remove the obstructions and clean out
the dust.
Let the device work for some time
until it has reached the selected
temperature.
The alarm sounds
and the display
panel DOES NOT
blink. (door alarm)
Has the door been open for more than 60
seconds?
Close the door or press the POWER
button to turn off the alarm. The alarm
will stop when the door is closed
The icon "-" is lit up
and blinking on the
display
The temperature on the Display is out of
range.
The appliance only shows temperatures
within a range of 0 ~ 99 ° F /-9 ~ 37 ° C.
If the temperature is not within this
range, the icon "-" with be displayed
instead.
Condensation on
the outside of the
door glass
High Humidity in the environment
During periods of high humidity, it may
appear drops of water on the outside of
the door glass. These will disappear
when the humidity level drops. It is
advisable to install the unit in a place
with sufficient ventilation, in a dry place
and / or with air conditioning.
The display
temperature does
not correspond to
the real one
Differential temperature relationship
between both zones is out of range.
Greater than 10 ° C
Lower temperature difference between
zones.