Page #6 background imageLoading...
Page #6 background image
[5]
[2]
[4]
[2 ]ND
[1]
[3]
[6]
[11]
[8]
[10]
[7]
[9]
[12]
[]
BYP
[]
MEM
[]
TRBL
- 6 -
stay arm / System A
enabled
enabled
enabled
Answering machine override
Bell squawk on arm/disarm
Auto zone shut-down
See " " TableREPORTING
(1:1.5) PULSE USA(1:2) PULSE EUROPE
enabledenabled
enabled
Auto arm on time
Auto arm on no movement
[5]
[2]
PS1/Keyswitch = regular arm / (A + B)
[4]
enabledCall back
[2 ]ND
[1]
See " " TableTLM
[3]
enabled
PS1/keyswitch arming
[6]
generates only a report
Silent zone/panic generates a silent alarm
[11]
[8]
[10]
[7]
Pulse dialing
Partitioning
Tone dialing (DTMF)
enabled
[9]
[12]
206:
KEY
[]
BYP
[]
MEM
[]
TRBL
OFF / ON
only after alarm
audible
enabled
audible
enabled
fire
on zone closure
4 digit
enabled
enabled
enabled
208:
OFF / ON
enabled
enabled
KEY
no EOL
Report zone restore on bell cut-off
Panic 2
Panic 3
See "Tamper/Wire Fault Definition Table"
Panic 1
Call PC when event list is full
Always report disarm
Panic 2 silent
Panic 1 silent (PS1)
Panic 3 silent
6 digit access codes
Key regular arm / (A + B)[10]
Key stay or system A arm[11]
Beep on exit delay
Zones with EOL (1K )green
(keys & )[1] [3], PS1
(keys & )[4] [6]
(keys & )[7] [9]
5
24
1
3
6
11 15
8
10 14
7
913
12 16
5
24
1
3
6
11 15
8
10 14
7
913
12 16
5
24
1
3
6
11 15
8
10 14
7
913
12 16
[2]
[1] [6]
[11]
[8]
[10]
[7]
[9]
[]
BYP
[]
MEM
[]
TRBL
[2 ]
ND
[12]
[5]
[4]
[3]
KEY SELECT:
CODE PRIORITY
202:
204:
SYSTEM "A" / STAY
SYSTEM "B" / AWAY
Codes with bypass access
200:
Note: Default = " " for addresses to
OFF
 
1) Press + installer code (default 747474). key will flash.
2) Enter 3 digit memory address ( to ).
3) Press corresponding key to select option.
4) To change selection press key again.
5) To save press .

 
 

6) Repeat steps 3 to 5 for addresses to
7) To exit programming mode press
 


Feature selection programming addresses to The " "/" " status of the lights (keys) determines features selected.
 
ON OFF
FEATURE SELECT (LIGHT ON/OFF) PROGRAMMING
PG728
TLM generates trouble only
TLM disabled
generates an alarm if armed
silent alarm becomes audible
(address , key has to be )206 [9] OFF
KEY
[2 ]
ND
[1]
OFF OFF
ONOFF
ON
ON
OFF
ON
TLM TABLE
(TLM = Telephone Line Monitor)
Address 206, Key [2 ] [1]ND
Exception: for 24 hour zones the tamper definition will follow the
audible/silent alarm definition of the 24 hour zone.
Silent zones will generate a silent alarm
Disabled
Alarm as per individual
zone definitions
KEY
No alarm, trouble code
reported
Audible alarm and trouble
codes reported
Silent alarm and trouble
codes reported
Always generate trouble
and alarm, audible or
silent as per individual
zone definitions
[11]
[10]
OFF OFF
OFF ON
ON OFF
ON ON
SYSTEM ARMED SYSTEM DISARMED
*
TAMPER / WIRE FAULT DEFINITION TABLE
Address 208, Key [10] [11]
*
**
**
OFF OFF
ONOFF
ON
ON
OFF
ON
REPORTING TABLE
Regular reporting 2,1,2,1,2,1,2,1, fail to comm.
Reporting disabled
Split reporting: Alarms
System report
1,1,1,1,1,1,1,1, fail to comm.
Double reporting
2,2,2,2,2,2,2,2, fail to comm.
2,2,2,2,2,2,2,2, fail to comm.,
1,1,1,1,1,1,1,1, fail to comm.
KEY
DIALING SEQUENCE
(tel. No.)
TYPE
[11]
[12]
On alarm, all reports are made to Tel. #1 until the system is disarmed.
(Once disarmed system reports are made to Tel. #2)
*
Address 206, Key [11] [12]
*

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox ESPRIT728 and is the answer not in the manual?

Paradox ESPRIT728 Specifications

General IconGeneral
BrandParadox
ModelESPRIT728
CategorySecurity Sensors
LanguageEnglish

Related product manuals