OPERATION & MAINTENANCE MANUAL
GUARDIAN
SPACE PRESSURE MONITOR
WITH REMOTE AUXILLARY ALARM
PARAGON CONTROLS INCORPORATED
P.O. BOX 99
FORESTVILLE, CALIFORNIA 95436-0099
(707) 579-1424
/SPM
REV. 7, 7/24/09
Question and Answer IconNeed help?

Do you have a question about the Paragon GUARDIAN and is the answer not in the manual?

Paragon GUARDIAN Specifications

General IconGeneral
BrandParagon
ModelGUARDIAN
CategoryMeasuring Instruments
LanguageEnglish

Summary

Basic Operation

Power Supply

Details the isolated linear type power supply and input power for the Guardian.

Alarm Status Indicators

Explains how normal and alarm status is indicated via LEDs on the face plate.

Alarm Configuration

Describes setting up positive or negative room pressure alarming based on setpoint.

Audible Alarm Acknowledge

How to mute the local audible alarm during a loss of required pressurization.

Remote Alarm Relay Function

Details the relay that energizes when the system is outside the acceptable operating range.

Remote Room Pressure Monitoring

Configuration for remote monitoring of positive or negative room pressure via dry contact.

Remote Auxiliary Alarm

Information regarding the optional remote auxiliary alarm system with adjustable delay.

Display Functionality

Explains the 3-1/2 digit LED display for space pressurization levels in engineering units.

Display and Setpoint Adjustment

How to use the LED display for indication and setpoint adjustment via a push button.

Key Locked Access Door

Details controlled access to configuration and adjustment functions via a key lock.

Central Module Configuration

Equipment for Configuration

Lists the necessary equipment, such as needle nosed pliers, for central module configuration.

Positive/Negative Alarming Setup

How to set up positive or negative space pressure alarming using jumpers H3 and H4.

Remote Pressure Selection Setup

Configuring remote selection of positive/negative space pressure via jumpers H3 and H4 to AUTO.

Audible Alarm Control

Using jumper H11 to activate or deactivate the local audible alarm function.

Analog Output Signal Configuration

Details the 0-10Vdc or 4-20mAdc analog output signal configurations via jumper H5.

Process Output Signal Selection

How to change the process output signal between voltage or current via jumper H5.

Pre-Startup Check

Equipment for Pre-Startup

Lists the equipment required for performing the pre-startup check, including a DMM.

Pre-Startup Verification Steps

Step-by-step checks to verify system functionality, LED illumination, and voltage readings.

Differential Pressure Transducer Calibration

Equipment for Transducer Calibration

Lists the equipment required for calibrating the differential pressure transducer.

Transducer Zero and Span Adjustment

Procedure to adjust the ZERO (R4) and SPAN (R10) potentiometers for the transducer.

-2.5v Reference, Analog Output, and Display Scaling Calibration

Equipment for Reference/Output/Display Calibration

Lists equipment for calibrating reference voltage, analog output, and display scaling.

Reference, Output, and Display Calibration

Procedure to calibrate the -2.5v reference, analog output, and display scaling.

Output and Display Scaling Adjustments

Details adjustments for CURRENT/VOLTAGE output scaling and LED display scaling.