TWP/TWB200 – TWP/TWB9000
7
Each elbow installed in the exhaust piping is equivalent to 10 feet of pipe. If the exhaust piping is vertical, a drip line
must be installed to remove moisture. It is recommended to pipe the exhausts separately for ease of maintenance
and troubleshooting.
It is highly recommended to install bypass valves and piping around the dryer and lters to use during routine dryer
maintenance.