3
2 Technical Specification
2.1 Technical Data
Flow Data
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 20ºC, 1 bar a, 0% relative water vapour pressure.
Performance
Operating Data
Electrical Data
Model
Pipe Size Flowrate
Inlet Outlet L/s
m
3
/min m
3
/hr
cfm
BA-DME012-E
G 1/2 G 3/8 11 0.68 41 24
BA-DME015-E
G 1/2 G 3/4 15 0.91 55 32
BA-DME020-E
G 1/2 G 3/4 19 1.19 71 42
BA-DME025-E
G 1/2 G 3/4 25 1.50 90 53
BA-DME030-E
G 1/2 G 3/4 31 1.84 110 65
BA-DME040-E
G 3/4 G 3/4 40 2.49 149 88
BA-DME050-E
G 1 G 1 50 3.01 180 106
BA-DME060-E
G 1 G 1 61 3.69 221 130
BA-DME080-E
G 1 G 1 83 4.99 299 176
Dryer Model
Pressure Dewpoint
(Standard)
ISO 8573-1:2010
Water Classification
o
C
o
F
(Standard)
BA-DME012 - 080
-40 -40
Class 2
(1)
(1) ISO 8573-1 classifications apply when the dryer is installed with the filtration supplied
Model
Min Operating
Pressure
Max Operating
Pressure
Min Operating
Temperature
Max Operating
Temperature
bar g psi g bar g psi g
o
C
o
F
o
C
o
F
BA-DME012 - 040
4 58 16 232 5 41 30 86
BA-DME050 - 080
4 58 13 188 5 41 30 86
BA-DME 012 - 040 BA-DME 050 - 080
Supply Voltage
207 - 253V 1PH 50/60Hz 207 - 253V 1PH 50/60Hz
Connection Type
IEC 60320 - C14 IEC 60320 - C14
Fuse
(1)
(1) Fuses are Anti surge (T), 250V, 5x20mm LBC, Breaking capacity 35A @250V, IEC60127-2, UL/CSA.
T500mA T500mA
Power
65 W 34W