EasyManua.ls Logo

Parker D1VW -SC Series - Series D1 VW; D1 DW

Parker D1VW -SC Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Directly operated and pilot operated directional control valves
Series D1VW / D1DW / D3W / D3DW / D31DW / D41VW / D81VW / D91VW
17
Translation from German
Parker Hannin Corporation
MSG11-5715-662 DCV UK.indd 21.07.22
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG06 / CETOP 03 / NFPA D03
Mounting interface DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03
Mounting position As desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
Weight (1 solenoid) [kg] 1.8
Hydraulic
Max. operating pressure [bar] P, A B: 350 ; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Max. contamination ISO 4406; 18/16/13
Flow max. [l/min] 80
Leakage at 50 bar [ml/min] Up to 10 per ow path, depending on piston
Static / Dynamic
Step response at 95 % [ms] Energized: 32 ; De-energized: 40
Electrical
Duty cycle 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 15000
Protection class IP 65 to EN 60529 (plugged and mounted)
Code K J U G
Operating tolerance [V] 12 V = 24 V = 98 V = 205 V =
Supply tolerance [%] ±10 ±10 ±10 ±10
Power consumption [A] 2.72 1.29 0.33 0.13
Power consumption [W] 32.7 31 31.9 28.2
Solenoid connection Connector to EN 175301-803, solenoid identication to ISO 9461
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Please note that with electrical connections the protective conductor (PE W) must be connected according to the
relevant regulations.
Series D1VW / D1DW
Technical data

Related product manuals