MSG11-5715-662 DCV UK.indd 21.07.22
Directly operated and pilot operated directional control valves
Series D1VW / D1DW / D3W / D3DW / D31DW / D41VW / D81VW / D91VW
18
Translation from German
Parker Hannin Corporation
General
Design Directional spool valve
Actuation Solenoid
Nominal size DIN NG10 / CETOP 05 / NFPA D05
Mounting interface DIN 24340 A10 / ISO 4401 / CETOP RP 121-H / NFPA D05
Mounting position As desired, horizontal mounting preferred
Ambient temperature [°C] -20...+60
Weight (1 solenoid) [kg] 5.2
Hydraulic
Max. operating pressure [bar] P, A, B: 350; T: 210
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -20...+70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Max. contamination ISO 4406; 18/16/13
Flow max. [l/min] 150
Leakage at 50 bar [ml/min] Up to 20 per ow path, depending on piston
Static / Dynamic
Step response at 95 % Energized: 105; De-energized: 85
Electrical
Duty cycle 100 % ED; CAUTION: coil temperature up to 150 °C possible
Max. switching frequency [1/h] 10000
Protection class IP 65 to EN 60529 (plugged and mounted)
Code K J U G
Supply voltage [V] 12 V = 24 V = 98 V = 205 V =
Supply tolerance [%] ±10 ±10 ±10 ±10
Current consumption Hold [A] 3 1.5 0.35 0.18
Power consumption Hold [W] 36 36 34 36
Connector Connector to EN 175301-803, solenoid identication to ISO 9461
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Please note that with electrical connections the protective conductor (PE W) must be connected according to the