26
IQAN-XT2 Technical Overview
Appendix A
Instruction book, IQAN-XT2
DOUT (on/off output)
Load current
each channel active (A,B,C,D,E,F)
3A
Load current
one channel in each group
(A or B, C or D, E or F)
4 A The DOUT’s are divided
into three groups.
Voltage drop (V
BAT
-V
DOUT
)
load I
L
= 0.5A
load I
L
= 2A
0.2
0.8
V
Off-State output current: TBD mA
Max load inductance: 200
1000
mH @ 2A
@ 1A
Short Circuit current limit 6 A
PWMOUT (open-loop)
Load current
each channel active (A,B,C,D,E,F)
3A
Load current
one channel in each group
(A or B, C or D, E or F)
4 A The PWMOUT’s are
divided into three groups.
Signal range TBD TBD % MR
Voltage drop (V
BAT
-V
PWMOUT
)
load I
L
= 0.5A
load I
L
= 2A
0.2
0.8
V
Off-State output current: TBD mA
Short Circuit current limit 6 A
Dither frequency, DF 25 2000 Hz
Resolution TBD % MR
EGAS
Load current 3 A
Min load TBD W Open load error
Short Circuit current limit 8 A T
A
= 25°C
PWM frequency 500 20000 Hz
a.Dependent on the master unit. Not implemented in the IQAN-XT2 unit.
b.Deviation of the output current at any command from its theoretical value (command value).
c.Deviation between any value and mean value with same command and load.
I/O
T
A
= +25 °C (unless otherwise specified)
Parameter
Limit values
Unit Remark
min. typ. max.