5
IQAN-XT2
3 Product description
Instruction book, IQAN- XT2
3 Product description
IQAN-XT2
The IQAN-XT2 is one out of several expansion modules designed for controlling
hydraulic systems in vehicles and machinery, using 12/24 Vdc power supply.
The IQAN-XT2 is able to be used in both IQANdevelop platform and IQANdesign
platform systems.
The IQAN-XT2 module.
Input
The IQAN-XT2 module has 10 voltage inputs for connecting of 0-5 Vdc signals.
VIN-H thru VIN-J can be configured as frequency inputs for measuring frequency.
Voltage inputs and frequency inputs, share positions, see below.
Output
The IQAN-XT2 module has two (2) double current outputs that are regulated for
controlling proportional valves. The module also has six (6) digital outputs for on/off
valves which can be configured as either six (6) individual or three (3) double PWM
outputs (Pulse Width Modulation) for non-regulated control of proportional valves and
devices. Digital and PWM outputs share positions, see below.
In order to increase the performance of current outputs when controlling proportional
valves, both the dither frequency and the dither amplitude can be adjusted.
The digital output channels also have soft start and peak & hold features available.
CAN related functions
The master uses the CAN-bus (CAN = Control Area Network) to communicate with
the modules. The CAN-bus is used and well proven within the automotive industry.
(10) Voltage inputs VIN-A, VIN-B, VIN-C, VIN-D.....VIN-J
or
(7) Voltage inputs VIN-A thru VIN-G and (3) Frequency inputs FIN-A thru FIN-C
(2) double Current outputs
(6) Digital outputs, or (3) double PWM outputs