29
Error codes, messages and actions
Appendix B
Instruction book, IQAN-XT2
ERROR: OUTPUT HIGH
Situation Error
code
Action IQAN-XT2 Comment
COUT:
Current return low
Error 1 Active output shuts
off.
Check load
COUT:
Current return high
Error 1 In current check
activated:
Active output shuts
off.
Check load
DOUT:
Overload
Error 1 Active output shuts
off.
Check load
COUT/DOUT:
Internal driver failure
Error 4 Active output shuts
off.
Contact supplier
EGAS:
Overload
Error 1 Active output shuts
off.
Check load