2. TECHNICAL SPECIFICATION
Type:
Model:
Outlet Dewpoint:
Air Quality:
(dirt/water/oil):
Maximum Operating Pressure:
Minimum Operating Pressure:
Maximum Inlet Temperature:
Minimum Inlet Temperature:
Regeneration:
Nominal pressure drop
across desiccant bed:
Standard Electrical Supply:
Controls:
Controller:
Noise Level (Average):
Media:
Material:
Construction:
Pre filtration:
After filtration:
A) GENERAL
Heatless
MPXE/MPXS
-40°C (-40°F)
-70°C (-100°F) - optional
ISO 8573.1 Class 1.2.1
Class 1.1.1 optional
13.0 bar g (189 psi g)
4 bar g (58 psi g)
50°C (122°F)
5°C (41°F)
Pressure Swing Adsorption (PSA)
[Air Purge Principle]
140 m bar (2 psi)
115/230V/1ph/50Hz/60Hz
Control equipment 24V ac.
MPXE - electronic with integrated display
MPXS - electronic
<85db (A)
Desiccant
High tensile extruded aluminium coated with Alocrom anti-corrosion
protection and paint finished with an abrasion resistant dry powder epoxy
coating.
PNEUDRI is constructed from extruded aluminium sections connected
together by high tensile bolts i.e. desiccant filled columns are contained
between an upper and lower manifold. The configuration varies between the
heatless and heat regenerative models as shown in figures 1 & 2
Grade AO/AA OIL-X filters
Grade AR OIL-X filter