Bulletin MSG30-3254-INST/UK
Installation and setup
manual
Electro-hydraulic control
for serie PVplus
Pump design series 44-45-46-47,
compensator design series 45
Eective: July 1st, 2021
Supersedes: March 1st, 2017
Visit our homepage
for additional support
parker.com/pmde

Other manuals for Parker PV016

Questions and Answers

  • C
    Christopher HernandezSep 13, 2025
    What to do if Parker Water Pump drive motor only turns at slow speed?
    • S
      Sherry SmithSep 13, 2025
      If the drive motor of your Parker Water Pump only turns at slow speed, consider the following: * **Motor selection:** Use a motor with more horsepower if the current motor is not selected properly. * **Hydraulic blockage:** Check the function of the pump compensator and start the pump at an unloaded system if the pump is hydraulically blocked.
  • T
    Tricia RoySep 15, 2025
    What to do if Parker PV016 Water Pump does not upstroke, sticks at zero displacement?
    • M
      Michelle MendozaSep 15, 2025
      If your Parker Water Pump does not upstroke and sticks at zero displacement, consider these potential causes: * **Contamination:** The compensator may be blocked due to contamination. Clean the hydraulic fluid and the compensator valve. * **Wiring issue:** The cable to the LVDT or proportional solenoid may be interrupted. Check the wiring and replace the cable if necessary.
  • S
    Scott SchneiderSep 16, 2025
    What to do if Parker Water Pump drive motor turns, but the pump does not turn?
    • S
      Sarah CollierSep 17, 2025
      If the drive motor of your Parker Water Pump turns, but the pump itself does not, check the coupling assembly and correct it, as it might not be mounted correctly.
  • B
    Brian HudsonNov 18, 2025
    What to do if Parker Water Pump delivers full flow at low pressure?
    • A
      Audrey HansenNov 19, 2025
      If your Parker Water Pump delivers full flow at low pressure, several issues could be the cause. The standard pressure compensator might be set to minimum pressure, so you should adjust the compensator setting to the desired pressure. Alternatively, the orifice in the remote pressure compensator could be blocked, so ensure the orifice Ø 0.8 mm in the control spool is free and open. Other potential causes include: a missing pressure pilot valve connected to port P. R (install a suitable pressure pilot valve and adjust it); an unenergized multiple pressure pilot selector valve (energize the selector valve solenoid); a missing load sensing line (connect the system load sensing port to the compensator); a closed or too small load sensing valve (open the load sensing valve or use a larger valve...

Summary

Proportional Displacement Control FDV

Proportional Displacement Control with Pressure Compensation UDR;UDK

Function Description UDR;UDK

Describes how pressure compensation overrides displacement control via a second control valve.

Proportional Displacement Control with Closed Loop Pressure Control UDM

Basic Adjustment of CIP Sensor

Basic Adjustment LVDT

Basic Adjustment Control Valves

Connecting Diagram for Proportional Displacement Control FDV

Connecting Diagram for p;Q-Control

Cables and Connections

Trouble Shooting Guide

Pump Delivers No Output Flow

Lists reasons and solutions for the pump not delivering any output flow.

Drive Motor Does Not Turn

Provides troubleshooting steps for when the drive motor fails to rotate.

Pump Does Not Build Up Pressure, but Delivers Full Flow at Low Pressure

Explains why the pump might deliver flow but fail to build adequate pressure.

Parker PV016 Specifications

General IconGeneral
BrandParker
ModelPV016
CategoryWater Pump
LanguageEnglish