EasyManua.ls Logo

Parker Racor 1000FH User Manual

Parker Racor 1000FH
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Turbine Series
900FH and 1000FH
Fuel Filter/Water Separators
Turbine Series filters protect
precision engine components
from dirt, rust, algae, asphaltines,
varnishes, and especially water,
which is prevalent in engine fuels.
They remove contaminants from
fuel using the following legendary
three stage process:
Stage 1 - Separation
As fuel enters the assembly, it
moves through the centrifuge and
spins off large solids and water
droplets, which are heavier than
fuel, and fall to the bottom of the
collection bowl.
Stage 2 - Coalescing
Small water droplets bead-up on
the surface of the conical baffle
and cartridge filter. When heavy
enough, they too fall to the bottom
of the collection bowl.
Stage 3 - Filtration
Proprietary Aquabloc
®
cartridge
filters repel water and remove
contaminants from fuel down to
2 micron (nominal). Aquabloc
cartridge filters are waterproof
and effective longer than water
absorbing filters.
Instruction Part Number 12960 Rev E
Contact Information
Parker Hannifin Corporation
Racor Division
P.O. Box 3208
3400 Finch Road
Modesto, CA 95353
phone 800 344 3286
209 521 7860
fax 209 529 3278
racor@parker.com
parker.com/racor
Getting Started
The following customer supplied
materials should be on-hand
before beginning installation.
• Shop Towels
• Diesel Fuel (about 1 gallon)
• Thread Sealant (no thread
tapes)
• Parker Super O-Lube
(RK31605) or equivalent
• Fuel Hose
• Mounting Hardware (3/8˝
or M10 fasteners)
• Inlet/Outlet Fittings
Question and Answer IconNeed help?

Do you have a question about the Parker Racor 1000FH and is the answer not in the manual?

Parker Racor 1000FH Specifications

General IconGeneral
BrandParker
ModelRacor 1000FH
CategoryWater Filtration Systems
LanguageEnglish

Summary

Turbine Series Product Overview

Installation Instructions

Element Replacement

Filter Replacement Criteria and Frequency

Defines when to replace the filter based on mileage, hours, or performance indicators.

Installing Optional In-Filter Heater

Heater Wiring Installation Precautions

Critical cautions and steps for safely installing the heater wiring, including fuse requirements.

Racor Heater Relay Kit Information

Heater Relay Wiring Schematic

Illustrates the 3-wire schematic for connecting the Racor heater using an external relay and battery.

900FH Specifications

900FH Replacement Parts

1000FH Specifications

1000FH Replacement Parts

Troubleshooting Common Issues

Seal Integrity and Air Ingestion

Addresses issues caused by damaged or worn seals and how to prevent air ingestion.

Fuel Leakage and Air Bubble Diagnosis

Troubleshooting fuel leaks and air bubbles appearing from the turbine or drain.

Drain Valve and Water Sensor Issues

Resolving problems with clogged self-venting drains and water sensor functionality.

Advanced Troubleshooting and Operation

Managing External Fuel Leaks

Immediate actions for external fuel leaks to prevent engine performance degradation.

New Filter Installation and Priming

Correct procedures for new filter installations, including priming and fuel system checks.

Water Sensor and Heater System Notes

Information on water sensor operation, heater functionality, and testing procedures.