Performance Information
Test results are from controlled laboratory testing. Field results may vary.
*PSI x 2.036 = inHg. (PSI x 6.895 = kPa)
SAE J1839 Water Separation
50 100 150
100
98
96
94
92
90
0
Time (minutes)
%
Efficient
4120490460445
8
6
4
2
0
PSI*
600500400300200100
Grams
SAE J905 Solids Capacity
SAE J905 Fuel Flow Restriction
1.0
0.6
0.4
0.2
1209060300
0.0
4120490460445
PSI*
Flow (GPH)
0.8
Installing Optional Features
Optional In-Bowl
Heater:
The in-bowl heater is a cold
weather starting aid with an
internal automatic thermostat
that turns the heater on if
fuel temperature drops below
45°F (7°C). Heat is supplied
just below the filter to melt
wax crystals and allow fuel to
efficiently pass through. The
heater will automatically turn
off at about 75°F (24°C). The
200 watt heater is available in 12
or 24 vdc (volts, direct current).
The heater is operated by turning
on the ignition switch for a
minimum of 5 minutes prior to
starting the engine.
Customer
Supplied Items:
Because of the heater power 1.
demand, 20 amps for the 12
vdc and 10 amps for the 24
vdc, an additional relay is
recommended for the safest
method of installation. Racor
offers two relay kits, available
from your dealer, RK 11861
for the 12 vdc systems or RK
11862 for the 24 vdc systems.
These kits include an in-line
fuse holder (and fuse) and the
RK 11862 kit also includes a
resistor. Use the 25 amp fuse
with the 12 vdc and the 15
amp fuse (and resistor) with
the 24 vdc systems. See page
11 for more details.
An on-off toggle switch may
2.
be used to control power
to heater relay. This allows
the operator to cut power to
heater relay during summer.
All wires should be 14 AWG
3.
(American Wire Gauge),
minimum.
Installation:
Either heater wire may be 1.
used for Hot (+) or Ground
(-).
Wire/terminal connections 2.
should be soldered and
crimped.
Run wires in protected 3.
locations. Avoid hot surfaces
and places that could pinch
or rub on the wires.
* Use the 15 amp fuse and resistor with 24 vdc systems.
Battery
- +
Ignition
Switch
* fuse* resistor
Relay
C4 B2
A5 E3
Connector
Fuse Box
1 amp fuse
Manual on-off
switch (optional)