EN | User Manual Start-up
K-MT 10-95/D3 25
Display panel
The display panel at the switchbox is equipped
with LEDs (light emitting diodes) and a digital
display, indicating the operating status of the
dryer:
Display panel at the switchbox
LED Power (1)
LED is on when dryer is switched on.
Flow diagram (2)
The current operating phases of the dryer are indicated by means of 4 LEDs:
Depending on the operating phase, the following LEDs might be on simultaneously:
Adsorption B1 and regeneration B2 or regeneration B1 and adsorption B2.
Digital display (3)
The digital display shows the individual programme steps and the respective remaining time.
For details regarding the sequence of the individual processing steps and their duration,
please refer to the logic control diagram, page 49.
Vessel B1
Regeneration 1
Adsorption 1
Vessel B2
Regeneration 2
Adsorption 2