EN | User Manual Maintenance and repair of the dryer
K-MT 10-95/D3 37
Depressurise the dryer and shut it down
(see page 31 ).
Unscrew muf er as shown in the opposite
gure.
Replace muf er and secure it.
Restart dryer (see page 32).
Undo muf er
Replace the element in the fi ne lter muffl er
Depressurise the dryer and shut it down
(see page 31 ).
Undo knurled screw on the lid cap and
remove cap.
Unscrew old  lter element. Arrows on the
element bottom mark the direction of rotation.
Insert new  lter element and screw on
tightly.
Renew muf er element
Re-engage lid cap at the top section of the housing and  x in position by means of the
knurled screw.
Restart dryer (see page 32 ).
Renew dewpoint sensor
To ensure precision dew point measurement,
it is recommended to replace the dew point
sensor every year. This period depends howev-
er on the actual application and might thus be
extended accordingly.
Dewpoint sensor (1)
Warning!
The dew point sensor is a sensitive measuring device. It can be damaged if
subjected to forceful vibrations or shocks. Therefore, please handle the dew
point sensor with great care at all times.