7. Depress the start lever on the spray
gun (10) until the pressure is released.
8. Please repeat steps 5. to 7. several
times until there is no further air in the
equipment.
Interrupting operation
Release the lever of the gun (
A
10).
During prolonged work intervals turn
off the washer by its ON / OFF switch
(
A
5).
Ending operation
After working with cleaning agents,
run the equipment with clean water to
completely rinse the cleaning agent
from the pipes.
Release the lever of the gun (
A
10).
Turn off the pressure by its ON / OFF
switch (
A
5).
Turn off the water tap.
Pull the lever of the gun (
A
10) to vent
the pressure existing within the system.
Pull the mains plug and wind up the
mains cable.
Disconnect the pressure washer from
the water mains.
Using detergents
The washer was designed for operation
with a neutral detergent based on a bio-
logically decomposable anionic tenside.
Other detergents or chemical substances
could impair the safety of the washer and
damage it.
F
Fixing the Wheels
Both of the front wheels can be fastened
in order to prevent the unintentional rolling
away of the pressure washer.
To do so, press both bolts (16) down-
wards. The wheels are now no longer
able to turn.
To cancel the wheel xing, push the
two bolts (16) upwards.
Cleaning and
Maintenance
Pull out the power plug before
every maintenance operation. There
is a risk of electrocution or of injury
from moving parts.
Cleaning
Never direct the water jet
against the washer, nor clean
the washer under owing
water. This could give rise to
the danger of electric shock
and damage the washer! .
Always keep the washer clean. Do
not use any detergents or solvents.
Always keep the ventilation slots clean
and free.
Only clean the pressure washer with a
soft brush or a slightly moist cloth.
In case a nozzle of the jet tube (
A
12/13) is clogged up, use the nozzle
cleaning pin (
A
7) to remove the ob-
ject from the nozzle.
E
If necessary, take off the water con-
nection with the lter insert (9) and
clean the lter insert.