8
Maintenance:
Leave it on or turn it off: The XP-12 is designed to be left on all the time. The exception
to this might be a case where the preamp will not be used for an extended time - in
that case it can be turn off.
Cleaning: The fi nish can be damaged by harsh cleaners and abrasive cloths. We
nd a damp soft cloth works best. You can also use a mild solution of windex or white
vinigar but be careful to avoid the acrylic wndow. The acrylic window should only be
cleaned using “plastic cleaner & polish”.
Remote batteries: The two AAA batteries should be replaced every six months at
least. The batteries are located under the remote back. This is held in place with four
4-40 phillips fl at head screws. Please note the polarity of the batteries, putting them in
wrong could cause damage.
Replacing the fuse: The fuse should only be replace with the same type and size as
indicated on the rear. Audio Specialty FUSE: NOTE: The “Overload” and “Time Delay
characteristics” will differ slightly (due to the different metallurgy of the fuse elements)
between commercial grade and audio grade fuses. We can’t guarantee that
your audiophile grade fuse, won’t blow at a different in-rush current threshold, than
your stock commercial fuse. Use of other than approved fuses, may invalidate your
product warranty and result in product damage.
XP-12 Specs:
Power consumption 30 Watts
Gain 9.3dB Balanced
Frequency response: +/- 0.05 dB 10Hz to 20KHz, -1dB @ 100KHz
Crosstalk > 100dB
Residual Noise 15uV 10 – 30Khz
THD < 0.001 @ 1V 1Khz
Dimensions: 17”w x 12.5”d x 4”h
Weight: 20lbs
How to replace the fuse: