3. Check if coin count input is configured properly for the
harness in Manage (see section “Error! Reference source
“Machine in Use”
during cycle
1. Check harness connection to BKSelect and to machine
2. Check if Inhibit/Available signals are configured properly
for the harness in Manage (see section “
Error! Reference
accept coins
1. Check if machine accepts coins if BluKey Select harness is
disconnected from the machine’s coin harness (can
disconnect harness from BluKey Select). If not, replace coin
acceptor and its harness.
2. Check machine’s wiring (a loose wire in connector pin
could be causing coin sensor/switch disconnects).
3. For optical coin sensors: Clean coin sensor optics or
replace coin sensor or coin acceptor assembly.