Operaon Systems— Waterway Neo 2100 Series Control, TruSwim® Models
40
ErrorCodes
Error caused when SENSOR 1 and
SENSOR 2 have been plugged in
incorrectly. Swap the SENSOR 1
and SENSOR 2 plug in controller to
correct this problem.
Clean lter.
Check SENSOR 1 connecon.
Clean lter, check jets in “on”
posion and valve open.
Error caused by no water ow through
heater or no water in heater.
Check to be sure there is enough
water ow through heater.
Clean lter.
Check SENSOR 1 connecon
or replace SENSOR 1.
Clean lter, check jets in “on”
posion and valve open.
Check to be sure there is enough water
ow through heater.
Wait for water temperature to cool down.
Wait for water temperature to cool down.
Check to be sure there is enough water
ow through heater.
Error caused when SENSOR 1,2, or 3
detects low temperature. All JETS and
BLOWERS will turn on automacally to
protect plumbing from freezing. JETS and
BLOWERS will shut down when all 3
SENSORS reach a desired temperature.
Clean lter.
Check SENSOR 2 connecon.
Clean lter, check jets in “on”
posion and valve open.
Check SENSOR 2 connecon
or replace SENSOR 2.
Clean lter.
Check SENSOR 3 connecon.
Check SENSOR 3
connecon or
replace SENSOR 3.