Do you have a question about the Peak Scientific Solaris XE and is the answer not in the manual?
Instructions for end users on how to navigate and utilize the manual effectively.
Explanation of symbols used in the manual to highlight specific areas for safe and proper use.
Crucial instructions for users regarding installation, operation, and maintenance safety practices.
Covers environmental parameters, inlet conditions, generator outlets, and electrical requirements for optimal performance.
Provides general information on dimensions and weight of the generator.
Guidance on inspecting the unit for transit damage and safe handling during removal from packaging.
Detailed steps for safely lifting and moving the generator, emphasizing a two-person lift.
Recommendations for situating the generator in a well-ventilated area with appropriate air gaps and temperature conditions.
Visual representation and measurements of the Solaris XE generator, including width, depth, and height.
Identification and description of rear panel connections including power switch, inlet, and outlet ports.
Important safety warnings regarding correct application connection and performing maintenance with the power off.
Details on connecting the generator to a suitable 100-230V single-phase supply, including safety classifications.
Information on correct wiring for EARTH/GROUND, LIVE, and NEUTRAL, emphasizing the need for earthing.
Notes that the unit can function pneumatically without electricity, affecting only specific features.
Details particulate, water, and oil specifications for the compressed air supply.
Recommendations for tubing diameter based on length to maintain optimal pressure between generator and application.
Explanation of front panel LED behaviour (YELLOW, GREEN) during the start-up and operation phases.
Instructions on how to adjust the output pressure using the front panel regulator and gauge, with a warning against exceeding factory settings.
Critical safety reminder to ensure the earth cable is attached before operating the generator.
Details the recommended annual maintenance kit and where to obtain it.
Overview of Peak Protected services including installation, complete/premium plans, IQ/OQ, spares, and technical support.
Instructions for cleaning the generator exterior using mild soap and water, emphasizing safety precautions.
Warnings against using solvents or abrasive solutions and advice on handling leak detection liquids.
A guide to diagnosing and resolving common issues such as failure to power on or pressure fluctuations.
Information on how to register the product for a 12-month on-site warranty online or via mail/email.
Explanation of the warranty period, registration deadline, and conditions for activation.
Highlights the global network of certified service engineers providing rapid response support.
Provides contact details for discussing Peak Protected cover and general product information.
The Solaris XE is a nitrogen generator designed for laboratory use, providing a reliable and continuous supply of nitrogen gas. This user manual serves as a comprehensive guide for its installation, operation, and maintenance, ensuring safe and efficient use. The device is intended for indoor use and can be installed adjacent to, underneath, or in between the application(s) it supplies, or mounted horizontally on a wall.
The primary function of the Solaris XE is to generate nitrogen gas from a compressed air supply. It is a fully pneumatic unit, meaning it can function without an electrical connection, although connecting it to power enables the pressure status indicator and LED lights on the front panel. The generator is designed to deliver nitrogen at a rated flow up to a maximum pressure of 116 psi (7.99 bar), assuming an adequate air supply. The output pressure can be adjusted using a regulator located at the front of the generator, with the current pressure displayed on an adjacent gauge. The system is engineered to provide nitrogen almost instantaneously once the air supply is turned on and adequate system pressure is reached. The generator requires an air supply that meets ISO8753-1:2010 Class 1.4.1 standards, ensuring the input air is free from excessive particulates, water, and oil, which is crucial for the purity of the generated nitrogen.
The Solaris XE is designed for straightforward operation. Upon initial startup, the LED on the front panel will illuminate yellow, indicating that the power is switched on and the system is initializing. Once the air supply is turned on and the internal system pressure reaches 80 psi, the fascia will illuminate green, signifying that the generator is ready to supply nitrogen. If the internal pressure is not met or is lost during operation, the LED will revert to yellow, prompting the user to check the input air supply.
Connecting the generator to an application involves using a ¼”- 6mm push fitting from the provided fittings kit to connect the generator's AIR IN and NITROGEN ports on the rear panel to the application's inlet using suitable 6mm tubing. The manual provides guidance on appropriate tubing lengths and diameters to prevent pressure drops and ensure optimal performance, recommending specific tubing types for different distances. For instance, for lengths under 10 meters, ¼” O/D, 3/16" I/D P.T.F.E. tubing is recommended. For lengths between 10 and 40 meters, 3/8” O/D, 5/16" I/D tubing is suggested, with a recommendation to contact Peak Scientific for tubing size calculations for distances over 40 meters.
The generator is equipped with a power switch, power inlet, compressed air inlet, and nitrogen outlet, all located on the rear panel. It requires a 100-230 volt single-phase electrical supply, and the manual specifies the correct wiring for earth, live, and neutral connections. While the unit can function without electricity, the pressure status indicator and LED lights will not be active.
Maintenance for the Solaris XE is designed to be user-friendly, with a recommended annual service schedule. The manual specifies that a Solaris Nitrogen XE Annual Maintenance Kit should be purchased every 12 months. Users are advised to use only Peak Scientific approved components for maintenance to ensure optimal performance and longevity of the generator.
For cleaning, the exterior of the generator should be wiped with a clean, damp cloth using warm soapy water. It is crucial to ensure that all excess fluid is thoroughly removed from the cloth before use. Importantly, cleaning should only be performed when the power is switched off and the power cord is disconnected from the rear of the generator. The manual explicitly warns against using solvents or abrasive cleaning solutions, as their fumes can be harmful to the generator. Care should also be taken when using leak detection liquids.
Troubleshooting guidance is provided for common issues. If the generator does not switch on or the power switch does not illuminate, users are advised to check if the power cord is properly plugged in and the socket is turned on, and to inspect the fuse in the power cord plug. If the fascia LEDs do not illuminate but the power switch is on, or if the yellow illumination does not change to green, or if the instrument reports low pressure, users are directed to check the air supply pressure to the generator and to contact their service provider. For low-pressure issues, checking for leaks between the generator and the instrument is also recommended.
Peak Scientific offers a "Peak Protected" aftercare program, which includes installation by a certified engineer, swift response for service and preventative maintenance, genuine spare parts with express delivery, and a technical support hotline. This program aims to ensure the generator's continuous operation and extend its lifetime. The product comes with a 12-month on-site warranty, which requires registration within one month of installation. If installation is deferred, Peak Scientific must be notified immediately to ensure the warranty remains active from the date of factory dispatch.
| Model | Solaris XE |
|---|---|
| Gas Type | Nitrogen |
| Frequency | 50/60 Hz |
| Power Output | Not applicable |
| Fuel Type | Not applicable |
| Purity | >99.5% |
| Certifications | CE, CSA |
| Weight | Varies by model |
| Outlet Pressure | Up to 100psi (6.9 bar) |