12.9. Command Set
Command line format
COMMAND<parameter1><parameter2>... [CR]
Hinweis:
Command code & return
value
Function
Example
Input Command:
GMAX[CR]
Return value:
<voltage><current>[CR]
OK[CR]
Get PS maximum Voltage
&current value
<voltage>=???
<current>=???
Input command:
GMAX[CR]
Return value:
180200[CR]
OK[CR]
Meaning:
Maximum Voltage is 18.0V
Maximum Current is 20.0A
Input Command:
SOUT<status>[CR]
Return value:
OK[CR]
Switch on/off the output of
PS
<status>=0/1 (0=ON, 1=OFF)
Input command:
SOUT0[CR]
Return value:
OK[CR]
Meaning:
Switch on the output of PS
Input Command:
VOLT<voltage>[CR]
Return value:
OK[CR]
Preset Voltage value
<voltage>=000<???<Max-Volt
*Max-Volt value refer to
product specification
Input command:
VOLT127[CR]
Return value:
OK[CR]
Meaning:
Set Voltage value as 12.7V
Input Command:
CURR<current>[CR]
Return value:
OK[CR]
Preset Current value
<current>=000<???<Max-
Curr
*Max-Curr value refer to
product specification
Input command:
CURR120[CR]
Return value:
OK[CR]
Meaning:
Set Current value as 12.0A
Input Command:
GETS[CR]
Return value:
<voltage><current>[CR]
OK[CR]
Get PS preset Voltage &
Current value
<voltage>=???
<current>=???
Input command:
GETS[CR]
Return value:
150180[CR]
OK[CR]
Meaning:
The Voltage value set at 15V
and Current value set at 18A
-30