BEST CONTROL INSTALLATION GUIDELINES AND WARNINGS
PLEASE READ PRECAUTIONS AND WARNINGS ON PAGE 2 BEFORE PROCEEDING WITH INSTALLATION
REMOVE PRESSURE SWITCH FROM PUMP AND WIRE BEST CONTROL DIRECTLY TO PUMP.
 BEST CONTROL operates the pump to its maximum pressure.
 Install BEST CONTROL only in clean water applications.
 Always confirm pump and system characteristics before installation, see page 5.
 Confirm electrical characteristics of pump motor before installation, e.g. full load amps and voltage.
 Must always be installed in the vertical position, flow arrows up, electronic box level.
 Do not install any tap or tee between the pump and the BEST CONTROL.
 Install a pressure reducing valve between pump and BEST CONTROL when maximum pressure generated by
the pump exceeds 145 psi.
 Install a gate valve and a pressure gauge after the BEST CONTROL unit. This allows testing of the pump and
BEST CONTROL unit for efficiency and to confirm pump pressure.
WHEN TO USE PRESSURE TANK
- 6 -
A small pressure tank ( 1/2 to 2 gallons ) may be used:
1 - In case of pumps using BIAC switch starting system motors
.
It allows bi-metal switch strips to cool in such a way to warrant the regular pump restart.
2 - In case of minimal delivery demands.
It allows for reducing the pump start-ups.
( Example: a glass of water, ice-making machine, inverse osmosis systems, or old systems
with small losses).