Rear Panel
1 2 3
4
5
6 7 8 9
DESIGNED AND ENGINEERED IN U.S.A.
REFER ALL SERVICING TO PEAVEY
AUTHORIZED SERVICE CENTER
CAUTION
ALL TUBES 12AX7A
6505
EFFECTS PREAMP
A PRODUCT OF PEAVEY ELECTRONICS CORP.
5022 HARTLEY PEAVEY DRIVE
MERIDIAN MS. 39305, U.S.A.
SEND
BIAS
TEST
FUSE
100V
F8AL/250V
115V
F5AL/250V
220/240V
F3.15AL/250V
100-240V
50/60Hz
400 WATTS
Consumo de energia 400Wh
Consumo de energia
en modo de espera 71Wh
BIAS
VOLTAGE
GND
RETURN OUT REMOTE SWITCH Made in ChinaCLASS 2 WIRING
SPEAKER OUTPUTS
120W RMS/44V RMS 4Ω MIN.
SPEAKER JACKS PARALLELED
100V
100V
240V
240V
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
7
8
9
10
CHANNEL
BRIGHT
CRUNCH
SELECT
HIGHMIDLOWPRE
INPUT
POST HIGHMIDLOWPRE POST RESONANCE PRESENCE RESONANCE PRESENCE
POWER
ONON
STANDBY
RHYTHM RHYTHM LEADLEAD
(1) LINE CORD (120 V units only)
For your safety, we have incorporated a 3-wire line (mains) cable with proper grounding facilities. It is
not advisable to remove the ground pin under any circumstances. If it is necessary to use the 6505ii
without proper grounding facilities, suitable grounding adaptors should be used. Greatly reduced
shock hazard exists when the unit is operated with the proper grounded receptacles.
(2) FUSE
WARNING: THE FUSE SHOULD ONLY BE REPLACED WHEN THE POWER CORD
HAS BEEN DISCONNECTED FROM ITS POWER SOURCE. A 5 amp fuse is located within the cap of the fuse
holder. It must be replaced with the same type and value in order to avoid damage to the equipment
and to prevent voiding the warranty. If the amp repeatedly blows fuses, it should be taken to a
qualied service center for repair.
(3) GROUND SWITCH
This is a three-position, rocker type switch which, for most applications, should be operated in
the center (zero) position. If hum or noise is noticed coming from the speaker enclosure(s) with
the Ground Switch in the center position, place the Ground Switch to positive (+) or negative (-)
to minimize hum. Should a hum/noise problem continue, consult your authorized Peavey dealer, the
Peavey factory, or a qualied service technician.
(4) BIAS TEST TERMINAL
These terminals, along with the adjustment knob behind the grill are provided to measure and adjust
the power amp tubes bias. The bias adjustment should only be done by a
alied technician.
(5) EFFECTS SEND/EFFECTS RETURN
Signals are supplied to outboard eects or signal processing units by patching from the Eects
Send output into the outboard unit(s) and back into the Eects Return input using shielded
cables with 1/4" mono phone plugs. Only non-gain eects devices (chorus, reverb, delay, etc.)
should be used in the eects loop. If footswitch is used, “Eects” must be selected (LED
illuminated) for eects to work.
(6) PREAMP OUT
This output can be used to send a preamp signal from the 6505 II to a mixing console, tape
recorder, etc., using a shielded instrument cable. Patching from the PREAMP OUT does not aect the
normal operation of the amplier.