WIRE GAUGE CHART
Stranded Power Power Power
Cable Wire Loss Loss Loss
Length Gauge Into Into Into
(Feet)
(AWG) 8 Ohms 4 Ohms 2 Ohms
5' 18 AWG .79% 1.58% 3.16%
16 .05 1.0 2.0
14 .31 .62 1.24
12 .20 .40 .80
10 .125 .25 .50
10' 18 AWG 1.58% 3.16% 6.32%
16 1.0 2.0 4.0
14 .62 1.25 2.50
12 .40 .80 1.6
10 .25 .50 1.0
40' 18 AWG 8% 12.6% 25.2%
16 4.0 8.0 16.0
14 2.5 5.0 10
12 1.60 3.2 6.4
10 1.0 2.0 4.0
8 .625 1.25 2.50
80' 16 AWG 8.0% 16.0% 32.0%
14 5.0 10.0 20.0
12 3.2 6.4 12.8
10 2.0 4.0 8.0