5. Install pressure regulator supplied with ovens. An adequate gas supply
is imperative, so that a manifold pressure of 4” WC for natural gas and 10”
WC for Propane units can be manifold pressure of 4” WC for Natural gas
and 10” WC for Propane units can be maintained with all units operating.
any kind.
7. To light pilot; open front access door, depress red button on the pilot
safety valve and light pilot burner. Maintain pressure on red button for 30
to 45 seconds, then release. If pilot goes out, repeat above procedure.
for the unit to operate.
9. Necessary adjustments have been made at the factory; however, units
should be checked at the place of installation to allow for local conditions.
10. Turn burner valve “ON” set thermostat to desired temperature, make
sure burner ignites before leaving the room.
12. During normal operation; if the pilot goes out, wait 5 minutes before
attempting to relight the oven. This allows any accumulated gas to
dissipate.
13. To shut oven down, turn thermostat and oven burner valve to the “OFF”
position. Disconnect gas supply after pilot has gone out. Repeat steps 6
and 10 to relight.