PLUS300 EXPERT U THR
Pag. 22
USE AND MAINTENANCE MANUAL
Rev. 01-18
rn3
Phase 3 refreshment
0 = NO
1 = YES
0
v3
Phase 3 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t3
Phase 3 duration
0:00...99:30
(30 min steps)
0:00
St4
Phase 4 temperature setpoint
-45 ÷ +45°C
0
SU4
Phase 4 humidity setpoint
0...99 rH%
0 = Disabled
60%
rn4
Phase 4 refreshment
0 = NO
1 = YES
0
v4
Phase 4 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t4
Phase 4 duration
0:00...99:30
(30 min steps)
0:00
St5
Phase 5 temperature setpoint
-45 ÷ +45°C
0
SU5
Phase 5 humidity setpoint
0...99 rH%
0 = Disabled
60%
rn5
Phase 5 refreshment
0 = NO
1 = YES
0
v5
Phase 5 evaporator fans speed. Amends
the value of 2nd level variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
t5
Phase 5 duration
0:00...99:30
(30 min steps)
0:00
St
Seasoning/preservation temperature
setpoint
-45 ÷ +45°C
0
SU
Seasoning/preservation humidity setpoint
0...99 rH%
0 = Disabled
60%
tSC
Seasoning/preservation end timeout
0 ÷ 240 days
0
vSC
Seasoning/preservation evaporator fans
speed. Amends the value of 2nd level
variable (F8)
0 = High speed
1 = Low speed
(only if rin = 1)
0
GERMINATION DAY/NIGHT CYCLE
To access the day/night cycle parameters for germination lights it is necessary to:
1. Check that parameter Cg = 1 .
2. Keep keys () DOWN and LIGHT pressed for a few seconds.
3. Using key () or key () select the parameter to be amended.
4. Amend the setting by keeping the SET key pressed and by pressing one of the keys
() or ().