PelPro Pellet Stove • 7104-171C • 10/3/18 pelprostoves.com22
Maintaining Your Stove
Where, When and How
Maintaining Your Stove
WARNING!
Disconnect Stove from power supply before servicing
Disposal of Ashes
Ashes should be placed in a metal container with a tight tting lid. The closed container of ashes should be placed
on a non-combustible oor or on the ground, well away from all combustible materials, pending nal disposal. If
the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed
container until all cinders have been thoroughly cooled.
Zone 1 - Firebox
Fire pot
Remove the re pot
Scrape clean and remove ashes
Replace re pot
Firebox
Remove ba󰀪es and vacuum residual ash
Remove ashes from rebox oor
WEEKLY AS NEEDEDOR
WARNING!
If using a vacuum to clean Stove, be sure embers are thoroughly cooled to prevent a re in the
vacuum.
1
Zone
1
Zone
3
Zone
3
Zone
2
Zone
2
Zone
Glass
Apply ceramic glass cleaner
Use non-abrasive cloth to remove residue
Door Inspection
The gasket between the glass and rebox should be inspected periodically to make sure there is a good
seal.