EasyManua.ls Logo

Pelpro PP130 - Blockage Related

Pelpro PP130
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PelPro Pellet Stove • 7104-171C • 10/3/18 pelprostoves.com30
Troubleshooting
Troubleshooting
Rumbling/whistling noise during operation
Conrm exhaust path is clean and clear (Zone 1 & 3)
- Adjust air/fuel ratio using trim adjustment dial (See page 18 for trim adjustment instructions)
1
Zone
1
Zone
3
Zone
3
Zone
2
Zone
2
Zone
Blockage Related
Black soot on outside of house
Conrm exhaust path is clean and clear (Zone 1 and 3)
- Adjust air/fuel ratio using trim adjustment dial
(See page 23 for trim adjustment instructions)
Ensure termination cap has at least 18” clearance to
reduce the e󰀨ects of soot blow-back on home exterior
(ie. siding)—if not able, refer to page 10 for alternate
installation options
Stove will not light
Conrm rebox is clean and clear (Zone 1)
- Igniter is getting hot (glows orange)
Inspect Stove body (Zone 2)
- Conrm fuel is in hopper, close lid securely
- Remove right side panel to access and conrm vacuum switch is clear and
connected at both ends
- Conrm all exhaust blower connections ...........secure
- Conrm the feed assembly and motor are clean and clear of debris
Conrm exhaust path is clean and clear (Zone 3)

Related product manuals