Troubleshooting
Troubleshooting
Blockage Related
Fire starts but goes out
Conrm rebox is clean and clear (Zone 1)
- Ensure re pot holes are clear
Inspect Stove body (Zone 2)
- Conrm exhaust probe is connected
- Inspect and clean the exhaust outlet
Conrm exhaust path is clean and clear (Zone 3)
Starts and stops frequently in automatic mode
Determine if your room is experiencing varying temperatures due to repeated opening/closing of doors or
windows—correct if necessary
Examine Stove body (Zone 2)
- Inspect ambient probe and conrm that at least 2” is exposed outside of Stove body
1
Zone
1
Zone
3
Zone
3
Zone
2
Zone
2
Zone
Slow or smoky start-up and/or lazy ame
Conrm exhaust path is clean and clear (Zone 3)
Examine Stove body (Zone 2)
- Align igniter so it is properly placed and centered
- Review fuel quality (see Pellet Fuel information on page 13)