7
Installing Your Stove
Installing Your Stove
Getting Ready (Continued)
Pellet Venting
Adding bends in the exhaust path restricts air ow, reduces
performance and provides a collection point for ash deposits
requiring more frequent cleaning.
REQUIRED:
Use only 3” or 4” type “L” or “PL” pellet pipe.
C
C
CAUTION
Do not connect to any air distribution duct or system
Do not install a ue damper in the exhaust venting system of this
Stove
Do not connect this Stove to a chimney ue serving another Stove
The structural integrity of the manufactured home oor, wall and
ceiling/roof must be maintained
Pro Tip
This Stove can be installed with a 3 to 6 inch (76-152mm) Top Vent O󰀨set Adapter Kit. The
3 to 6 inch (76-152mm) Top Vent O󰀨set Adapter are tested to use 24 gauge single wall ue
connector or Listed double wall ue connector to Class A Listed metal chimneys, or masonry
chimneys meeting International Conference of Building O󰀩cials (ICBO) standards for solid
fuel Stoves.
Caution, do not pass connector pipe through a combustible wall or ceiling. Please refer to
connector pipe installation instructions for details.
Installation Video
Visit pelprostoves.com or scan this code:

Related product manuals