PP60 TROUBLE SHOOTING MANUAL
8-5-2013
8 FLASHES: EXHAUST OVER TEMPERATURE
CHECK TO MAKE SURE THE FIREBOX
AREA, EXHAUST PIPE AND FIREPOT
IS CLEAN.
CHANGE TO
APPROVED FUEL
AND RESTART
UNIT.
SYSTEM IS
REPAIRED
IS APPROVED FUEL
BEING USED IN THE
UNIT?
YES
NO
MAKE SURE THE
CORRECT
CONTROL BOARD
IS INSTALLED.
MAKE THE REPAIR BY
CLEANING OR
REPLACING THE
COMPONENT OR
REPLACING THE
CONTROL BOARD
IS THE FEED MOTOR
RUNNING IN A CYCLE
MODE?
1 TO 4 SEC “ON TIME”
EVERY 7 SEC
HOME
HOME
PAGE 3
YES
NO
IS THE FUSE IN
THE CONTROL
BOARD GOOD?
IS THE
CONVECTION
BLOWER
COMING ON?
YESYES
NONO
IS THE
CONVECTION
BLOWER CLEAN?
YES
NO

Other manuals for Pelpro PP60

Related product manuals