PP60 TROUBLE SHOOTING MANUAL
8-5-2013
LAZY OR SOOTY FLAMES
HOME
HOME
PAGE 4
CHECK TO MAKE SURE THE FIREBOX
AREA, BAFFLES, EXHAUST PIPE AND
FIREPOT IS CLEAN.
CHANGE TO
APPROVED FUEL
AND RESTART
UNIT.
SYSTEM IS
REPAIRED
IS APPROVED FUEL
BEING USED IN THE
UNIT?
YES
NO
MAKE SURE THE
CORRECT
CONTROL BOARD
IS INSTALLED.
MAKE THE REPAIR BY
CLEANING, REPLACING
THE COMPONENT OR
REPLACING THE
CONTROL BOARD
IS THE FEED MOTOR
RUNNING IN A CYCLE
MODE?
1 TO 4 SEC “ON TIME”
EVERY 7 SEC
YES
NO
IS THE FUSE IN
THE CONTROL
BOARD GOOD?
IS THE
EXHAUST
BLOWER
RUNNING?
YES
YES
NO
NO
WILL THE HEAT
OUTPUT
CONTROL LOWER
THE FLAME
HEIGHT?
YES
NO
WILL THE
TRIM CONTROL
ADJUST THE
FLAMES?
YES
NO