INSTALLATION AND
OPERATION MANUAL
LTH SERIES SELF-PRIMING
CENTRIFUGAL PUMP
LTH-1
LTH-1-1/2
LTH-2
LTH-2-1/2
BERKELEY

Questions and Answers

  • J
    jamesacostaAug 11, 2025
    How to fix Pentair BERKELEY LTH Water Pump if it does not deliver water to full capacity?
    • R
      Richard SnyderAug 12, 2025
      If your Pentair Water Pump isn't delivering water to its full capacity, consider these potential issues: * A leaking foot valve may be causing a loss of priming. Replace the foot valve. * The water level in the well might be more than 25 feet below the pump's suction point. A deep well jet pump may be necessary. * Steel piping (if used) could be corroded or limed, causing excess friction. Replace it with plastic pipe where possible, or use new steel pipe. * Offset piping might be too small. Use larger offset piping.
  • S
    Susan CookAug 20, 2025
    What to do if my Pentair Water Pump motor will not run?
    • C
      Christine CrawfordAug 20, 2025
      If your Pentair Water Pump motor isn't running, there are several potential causes: * The disconnect switch might be off. Ensure the switch is turned on. * A fuse might be blown. Try replacing the fuse. * The starting switch could be defective. Consider replacing it. * Wires at the motor might be loose, disconnected, or incorrectly wired. Refer to the wiring instructions and check/tighten all wiring. Be cautious of capacitor voltage; discharge the capacitor with an insulated screwdriver if needed, or consult a qualified electrician.
  • T
    Thomas JacobsAug 27, 2025
    Why does my Pentair BERKELEY LTH motor run hot and overload kicks off?
    • C
      Christopher KingAug 27, 2025
      If your Pentair Water Pump motor runs hot and the overload kicks off, it could be due to: * Incorrect wiring. Refer to the wiring instructions. * Voltage that is too low. Check with your power company and consider installing heavier wiring if the wire size is too small (refer to the Electrical section of the manual).
  • S
    Sydney SnowNov 4, 2025
    Why does my Pentair BERKELEY LTH motor run, but no water is delivered?
    • D
      Dennis RamosNov 4, 2025
      If your Pentair Water Pump motor runs but isn't delivering water, check the following: * If it's a new installation, the pump may not have picked up prime. Unscrew the priming plug to ensure the pump case is filled with water, re-prime according to instructions, check all suction line connections, and replace the foot valve if necessary. * If the pump has lost prime in an existing installation, unscrew the priming plug to check for water in the pump case, inspect all suction line connections and the shaft seal, lower the suction line into the water, and re-prime. If the water level is too low for suction lift, a deep well pump may be required. * The impeller might be plugged. Clean it according to the impeller cleaning/replacement procedures. * The check valve or foot valve might ...

Summary

Safety Information

General Safety

General safety precautions and warnings for pump operation.

Electrical Safety

Guidelines and warnings for safe electrical connections and usage.

Installation

Prior to Pump Installation

Essential checks and preparations before installing the pump.

Well Pipe Installation

Procedures for installing suction pipes based on well casing types.

Operations

Priming the Pump

Procedure to expel air and start water flow in the pump system.

Troubleshooting Chart

Pentair BERKELEY LTH Series Specifications

General IconGeneral
BrandPentair
ModelBERKELEY LTH Series
CategoryWater Pump