INSTALLATION AND
OPERATION MANUAL
SELF-PRIMING CENTRIFUGAL PUMP
LTHH SERIES
3621 0714 ASB

Questions and Answers

  • C
    Caleb SmithAug 5, 2025
    What to do if my Pentair Water Pump motor will not run?
    • T
      Tonya MorrisAug 5, 2025
      If your Pentair Water Pump motor isn't running, there could be several reasons. First, ensure the disconnect switch is turned on. If it is on, check the fuse and replace it if it's blown. A defective starting switch could also be the culprit, in which case it should be replaced. Lastly, inspect the wiring at the motor for looseness, disconnections, or incorrect wiring. Refer to the wiring instructions to correct any issues. Remember that capacitor voltage can be hazardous, so discharge the capacitor with an insulated screwdriver if necessary, or consult a qualified electrician.
  • C
    Cheryl PowellAug 21, 2025
    Why does my Pentair Berkeley LTHH motor run hot and overload kicks off?
    • J
      Jason MoraAug 21, 2025
      If your Pentair Water Pump motor runs hot and the overload protection activates, it could be due to incorrect wiring. Refer to the wiring instructions to ensure it's properly connected. Another possibility is low voltage. Contact your power company to check the voltage, and if the wire size is too small, install heavier wiring, referring to the electrical section of this manual for guidance.
  • J
    Justin JosephAug 28, 2025
    How to fix Pentair Berkeley LTHH Water Pump that does not deliver water to full capacity?
    • L
      lynchcrystalAug 28, 2025
      If your Pentair Water Pump isn't delivering water to its full capacity, a few things could be the cause. A leaking foot valve might be causing a loss of priming, in which case you should replace the foot valve. If the water level in your well is more than 25 feet below the pump's suction point, you might need a deep well jet pump. Also, if you're using steel piping, corrosion or lime buildup could be creating excess friction; consider replacing it with plastic pipe where possible, or with new steel pipe. Finally, check if the offset piping is too small and replace it with larger diameter piping.
  • M
    Megan PalmerNov 12, 2025
    What to do if Pentair Berkeley LTHH Water Pump motor runs but no water is delivered?
    • D
      Daniel LeeNov 12, 2025
      If your Pentair Water Pump motor runs but no water is being delivered, several factors could be at play. If it's a new installation, the pump might not have picked up prime due to improper priming, air leaks, or a leaking foot valve. Re-prime the pump according to the instructions, check all connections on the suction line, and replace the foot valve if needed. If the pump has lost prime in an existing installation, check for air leaks in the suction line and shaft seal, and ensure the water level hasn't dropped below the suction point. Lower the suction line into the water and re-prime the pump. Also, the impeller could be plugged, so clean it following the impeller cleaning procedures. Other potential issues include a stuck check valve or foot valve (replace if necessary), frozen pipes (...

Summary

Safety Instructions

General Safety Precautions

Provides general safety guidelines for operating and maintaining the pump.

Electrical Safety Guidelines

Covers essential electrical safety precautions for wiring and grounding the motor.

Pump Installation Procedures

Prior to Pump Installation

Steps to follow before installing the pump, ensuring proper setup and operation.

Well Pipe Installation

Procedures for installing suction pipes in cased and dug wells.

Driven Point Installation

Steps for connecting suction pipe to a driven point, including check valve installation.

Installation Details and Applications

Discharge Pipe Sizing

Guidance on selecting appropriate discharge pipe sizes based on run length.

Lawn Sprinkling Application

Details on the pump's design for lawn sprinkling and its limitations.

Pump Installation

Instructions for physically installing the pump and supporting piping.

Electrical Connections and Wiring

Motor Voltage Configuration

Steps for setting the motor voltage for dual-voltage models.

Power Supply Connections

Guidelines for connecting the pump to the power supply safely and correctly.

Electrical Wiring Chart

Recommended Wire and Fuse Sizes

A chart detailing recommended wire and fuse sizes based on model and distance.

Pump Operations and Maintenance

Priming the Pump

Detailed steps and warnings for priming the pump to ensure water delivery.

Pump Maintenance Procedures

Cleaning and Replacing Impeller

Instructions for cleaning or replacing the pump's impeller.

Removing the Old Shaft Seal

Procedures for removing and preparing to replace the shaft seal.

Pump Seal and Assembly Maintenance

Installing a New Shaft Seal

Step-by-step guide for correctly installing a new shaft seal.

Pump Reassembly

Steps for reassembling the pump after maintenance or seal replacement.

Troubleshooting Common Issues

Parts List and Identification

Limited Warranty Information

Pentair Berkeley LTHH Series Specifications

General IconGeneral
SeriesLTHH
ManufacturerPentair Berkeley
CategoryWater Pump
Voltage230V
Phase3
Seal TypeMechanical Seal