P15008 (04-15-2023)
HORSEPOWER VOLTAGE PHASE
MOTOR
TYPE
MAX. LOAD
AMPS
BRANCH
FUSE RATING
AMP
DISTANCE IN FEET (METERS) FROM MOTOR TO SUPPLY
0-100 (0-30) 101-200 (31-61)
201-300 (62-91) 301-400 (92-122)
AWG WIRE SIZE (MM^2)
1/2 115/230 1 ODP 8.5/4.3 15/15 14/14 (2/2) 12/14 (3/2)
10/14 (5.5/2) 8/14 (8.4/2)
1/2 230/460 3 ODP 2.3/1.15 15/15 14/14 (2/2) 14/14 (2/2)
14/14 (2/2) 14/14 (2/2)
1/2 115/230 1 TEFC 8.2/4.1 15/15 14/14 (2/2) 12/14 (3/2)
10/14 (5.5/2) 8/14 (8.4/2)
1/2 230/460 3 TEFC 2.2/1.1 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
3/4 115/230 1 ODP 11.4/5.7 20/15 14/14 (2/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3)
3/4 230/460 3 ODP 3.1/1.55 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
3/4 115/230 1 TEFC 11.6/5.8 15/15 14/14 (2/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/14 (14/2)
3/4 230/460 3 TEFC 2.9/1.45 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
1 115/230 1 ODP 12.2/6.1 25/15 12/14 (3/2) 8/14 (8.4/2) 8/14 (8.4/2) 6/12 (14/3)
1 230/460 3 ODP 3.6/1.8 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
1 115/230 1 TEFC 14.2/7.1 20/15 12/14 (3/2) 8/14 (8.4/2) 6/14 (14/2) 6/12 (14/3)
1 230/460 3 TEFC 3.6/1.8 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
1-1/2 115/230 1 ODP 18.4/9.2 30/20 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5)
1-1/2 230/460 3 ODP 4.7/2.35 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
1-1/2 115/230 1 TEFC 18.0/9.0 25/15 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5)
1-1/2 230/460 3 TEFC 4.8/2.4 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
2 115/230 1 ODP 22.8/11.4 45/25 10/14 (5.5/2) 6/12 (14/3) 6/12 (14/3) 4/10 (21/5.5)
2 230/460 3 ODP 6.8/3.4 15/15 14/14 (2/2) 14/14 (2/2) 12/14 (3/2) 12/14 (3/2)
2 230 1 TEFC 10.4 15 14 (2) 14 (2) 12 (3) 10 (5.5)
2 230/460 3 TEFC 6.0/3.0 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 12/14 (3/2)
2-1/2 115/230 1 ODP 22/11 45/25 10/14 (5.5/2) 8/12 (8.4/3) 6/12 (14/3) 4/10 (21/5.5)
2-1/2 230/460 3 ODP 8.5/4.25 15/15 14/14 (2/2) 14/14 (2/2) 12/14 (3/2) 10/14 (5.5/2)
2-1/2 230 1 TEFC 11.7 15 14 (2) 14 (2) 12 (3) 10 (5.5)
2-1/2 230/460 3 TEFC 7.0/3.5 15/15 14/14 (2/2) 14/14 (2/2) 12/14 (3/2) 12/14 (3/2)
TABLE II - RECOMMENDED FUSING AND WIRING DATA - 60 CYCLE MOTORS