TROUBLESHOOTING
Mandatory Leak Test Indicates a Leak
1. Turn off the pool pump at the circuit breaker and be sure all ow to the unit has been stopped.
2. Refer to pages 4-5 for “Quartz Sleeve Assembly” and page 8 for “UV Lamp Installation” (in reverse order) to
disassemble the unit.
3. Ensure there are no cracks or breakages in the Quartz Sleeve, that the Quartz Sleeve Gasket and O-ring are properly
installed, and that the Quartz Sleeve Retaining Nut has been tightened down completely
4. Reassemble the Quartz Sleeve (see page 4) and repeat the Mandatory Leak Test (see page 7) until there are no
indications of a leak.
GFCI/Breaker is Tripping
1. Immediately disconnect power to the Bioshield
®
UV Disinfection Sterilizer.
2. Turn off the pool pump at the circuit breaker and be sure all ow to the unit has been stopped.
3. Refer to pages 4-5 for “Quartz Sleeve Assembly” and page 8 for “UV Lamp Installation” (in reverse order) to
disassemble the unit.
4. Check for water/moisture inside the quartz sleeve.
5. Multiple appliances connected to a circuit protected by one GFCI create the potential for cumulative leakage current
resulting in a tripped GFCI.